Council archive · source document
06/2689 - Response to request for further Information [As Published] · 132006.2689
Very large file (19.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
As per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking, Section 5.3.1 the minimum height from the floor to any overhead obstruction (fire sprinkler, lighting, sign etc), allow for cars and light vans, should be 2.2m (2.3m if parking wil! be provided for people with disabilities, however as our disabled spaces will be on the ground level parking, 2.2m is considered sufficient for the basement). Headroom between the ramp and the entrance to the basement shall also be 2.2m however will be measured perpendicular to a chord of length equal to the wheelbase of the B99 vehicle located longitudinally such that the height is a minimum of 2.2m, as per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking Figure 5.3. The clearance from the floor to the ceiling in the basement will be 2.5m. This will allow for the installation of sprinklers, signs and lighting without reducing clearance to below the minimum 2.2m. The ramp terminates before entry to the basement and vehicles will enter on level ground. Therefore clearance at entry to the basement is considered adequate. Low Clearance signs (R6-16) to the basement will be provided as per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking, Section 4.3.4(a). Flexible striker bars will also be provided in conjunction with these signs where the clearance will be less than 2.3m due to sprinklers, lighting or signs. 2.3 VEHICLE ACCESS 2.3.1. Response to Point 6 Single access with revised traffic volumes has been analysed. As per Section 3.2.1 of AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking the access classifies as a Class 2 Access Facility. This requires a 6m (minimum) wide combined non-separated driveway access. Access will be made via a 6.0m two way driveway on the southern end of the site and therefore complies with the standards. The location of the access is shown on plans in Appendix A. As Council propose to construct an unbroken raised median past the site between Woodland Drive and Herron Drive, future access to the site will be restricted to left in and teft out only. As there is no shoulder on David Low Way and therefore no provision for passing a turning vehicle, the warrants for turning lanes at the access, as per DMR’s Road Planning and Design Manual, Chapter 13 — Intersections at Grade (RPDM), Figure 13.23 was assessed. This shows an AUL(S) (short left turn treatment) is warranted on David Low Way into the access. eo vem BURCHILL VDM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.