06/2689 - Response to request for further Information [As Published] · 132006.2689
Very large file (19.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
4,3. It is further noted that the driveway ramp grades need to be determined based on the inside radius of the ramp (i.e. where the ramp grades will be steeper) as opposed to the grade at the centre of the ramp. This is outlined in the Australian Standard for Off-Street Car Parking (AS2890.1) and will need to be addressed. _ Response Please refer to the traffic engineering response prepared by Burchill VDM which addresses this matter. The proposal plans prepared by Ken Down Architects namely the Basement/Site Plan Drawing No. 2243 SD02 Revision E has been revised in line with recommendations from the traffic engineering response. 4.4. Furthermore, the applicant will need to demonstrate in accordance with Specific Outcome 017 of Table 14-46 of the Driveways & Carparking Code that abasement level of RL7.1 (as presently proposed) can in fact drain by gravity means without the need for pumping. In this regard the applicant will need to arrange a surveyor to establish the invert levels of Council's existing drainage system and demonstrate how the basement will be drained to this drainage system. If this cannot be achieved the applicant will need to investigate the option of raising the basement level (to ensure the basement can drain by gravity means) and/or upgrading the existing Council drainage system such that it is at a level that can drain the basement carpark. These issues will need to be resolved prior to Council issuing a Development Permit for the proposed Material Change of Use as Council must be sure that the development is suitable and can actually work. Response Please refer to the Stormwater Management Report prepared by Barlow Gregg VDM which addresses this matter. Car Parking Item 5 Demonstrate that the proposed driveway and carparking area comply with all aspects of the Australian Standard (AS2890.1) for Parking Facilities, Part 9: Off Street Car Parking. 5.1. In this regard it is noted that the present proposal contains blind corners and blind aisles with no provision for vehicles to turn around. As such designated turning bays must be provided and it is recommended that they be at least 3m wide (to allow ease of access and departure) and at least 5.4m long. To this end: .One turning bay should be provided adjacent to the proposed stairs located at the south- eastern comer of the basement (space number 30), and .One turning bay should be provided on the eastern side of the basement immediately to _the north of the proposed tank (space number 22). Response Please refer to the traffic engineering response prepared by Burchill VDM which addresses this matter. The proposal plans prepared by Ken Down Architects namely the Basement/Site Plan Drawing No. 2243 SDO2 Revision E and Ground Floor Plan Drawing No. 2243 SD02 Revision
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.