Council archive · source document
06/2689 - Response to request for further Information [As Published] · 132006.2689
Very large file (19.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
G has been revised in line with recommendations from the traffic engineering response. "5.2. The proposed driveway ramp that provides access to the carpark needs to be amended as: . It appears that two laneways will need to be separated by a cental median, with each lane having a minimum width of 3.9m measured between kerbs. . The proposed ramp grades must be determined by the inside radius of the ramp (i.e. where the ramp grades will be steeper) not the middle of the ramp. .Headroom between the ramp and the entrance to the basement carpark must be designed such that vehicles will not hit the upper level as this will require changes to the upper level and/or the driveway grades. Response Please refer to the traffic engineering response prepared by Burchill VDM which addresses this matter. The proposal plans prepared by Ken Down Architects namely the Basement/Site Plan Drawing No. 2243 SD02 Revision E has been revised in line with recommendations from the traffic engineering response. 5.3. Amend the proposal plan such that clear access is available to all stairs cases. In this regard it is noted that clear access cannot be obtained to the proposed stair at the south- eastern comer of the upper level carpark. A clear passage of at least 1.5m in width should be available to the stairs, free of any carparking spaces or wheel-stops that would impede .pedestrian movements. Response Please refer to the amended proposal plans prepared by Ken Down Architects namely the Ground Floor Plan Drawing No. 2243 SDO2 Revision G which has been revised such that the proposed stair is clear of car parking and sufficient pedestrian movement is achieved. 5.4. Given the overall size of this development and the number of separate tenancies Proposed please provide at least 2-disabled car park spaces on site. Response Please refer to the amended proposal plans prepared by Ken Down Architects namely the Ground Aoor Plan Drawing No. 2243 SD02 Revision G which has been revised to include 2 disabled car parking spaces. Vehicle Access Item 6 The proposed separated entry and exit for the development, similar to that which exists for the existing house on site, is not suitable for a development of this scale and likely traffic generation and would result in countless conflicts between vehicles and pedestrians using the footpath especially given that the driveway has a width of approximately 25m which coincides with the pedestrian path. The angle of the entry and exit would also cause vehicles to enter and leave the site at faster speeds which is not conducive for pedestrian safety and nor are adequate sight lines available.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.