G has been revised in line with recommendations from the traffic engineering response.
"5.2. The proposed driveway ramp that provides access to the carpark needs to be amended
as:

. It appears that two laneways will need to be separated by a cental median, with each lane
having a minimum width of 3.9m measured between kerbs.

. The proposed ramp grades must be determined by the inside radius of the ramp (i.e.
where the ramp grades will be steeper) not the middle of the ramp.

.Headroom between the ramp and the entrance to the basement carpark must be designed
such that vehicles will not hit the upper level as this will require changes to the upper level
and/or the driveway grades.

Response
Please refer to the traffic engineering response prepared by Burchill VDM which addresses this
matter. The proposal plans prepared by Ken Down Architects namely the Basement/Site Plan
Drawing No. 2243 SD02 Revision E has been revised in line with recommendations from the
traffic engineering response.

5.3. Amend the proposal plan such that clear access is available to all stairs cases. In this
regard it is noted that clear access cannot be obtained to the proposed stair at the south-
eastern comer of the upper level carpark. A clear passage of at least 1.5m in width should
be available to the stairs, free of any carparking spaces or wheel-stops that would impede
.pedestrian movements.

 

 

 

Response

Please refer to the amended proposal plans prepared by Ken Down Architects namely the
Ground Floor Plan Drawing No. 2243 SDO2 Revision G which has been revised such that the
proposed stair is clear of car parking and sufficient pedestrian movement is achieved.

 

5.4. Given the overall size of this development and the number of separate tenancies
Proposed please provide at least 2-disabled car park spaces on site.

Response

Please refer to the amended proposal plans prepared by Ken Down Architects namely the
Ground Aoor Plan Drawing No. 2243 SD02 Revision G which has been revised to include 2
disabled car parking spaces.

Vehicle Access

Item 6

The proposed separated entry and exit for the development, similar to that which exists for
the existing house on site, is not suitable for a development of this scale and likely traffic
generation and would result in countless conflicts between vehicles and pedestrians using
the footpath especially given that the driveway has a width of approximately 25m which
coincides with the pedestrian path. The angle of the entry and exit would also cause
vehicles to enter and leave the site at faster speeds which is not conducive for pedestrian
safety and nor are adequate sight lines available.

 

 

 

Used in these records

About this file

File size
19.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_2689 - Response to request for further Information [As Published].pdf · 19.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.