Council archive · source document
06/2689 - Response to request for further Information [As Published] · 132006.2689
Very large file (19.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
13 5.0 INTERNAL ANALYSIS 5.1 LAYouT A two way, 6.0m wide driveway access will be constructed as per AS 2890.1: 2004 Parking facilities — Off-street car parking, and Council's Noosa Plan 2006 — Part 14 Assessment Criteria for Development for a Stated Purpose or of a Stated Type and is considered adequate for the site. The internal road layout will provide access from the driveway to the ground level parking and the basement parking area via ramp. Drawings C3694-002, C3694-003 and C3694-004, Appendix E shows all vehicles can enter the site and park and leave in a forward direction. Vehicles expected to enter the site will be cars and light vans including service and delivery vehicles. Garbage trucks will service the site from David Low Way within the left turn lane so as to not obstruct through vehicles on David Low Way. As per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking, the grade on curved ramps shall be measured at the inside edge of the curve, i.e. at the inside line marking. As per the standard, ramp grades on the inside edge of the curve will need to be no greater than 1 in 6, with Grade Transitions of 2.0m on length at the top and bottom of the ramp. Ramp grades on the inside edge of the curve will be the same as those shown on the middle of the ramp on Drawings 2243 SD02 and 2243 SDO3 (Appendix A). These grades comply with the requirements of AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking. As per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking the minimum ramp widths on the straights should be 5.5m. On the curves lane widths should be 3.9m with a central median of 0.6m giving a total width of 8.4m. Ramp widths on the straight at the top of the ramp will be approximately 5.6-5.9m, which complies with the standards. However, due to the physical restraints of the site, the widths on the curve of the ramp will be approximately 6.5-7.3m without a central median. However, as shown on Drawing C3694-004, Appendix E, there is sufficient space for a B85 and B99 vehicle to pass without conflicts on the ramp, as per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking, Section 2.5.2(c). As shown in Drawing C3694-004, there will be conflicts on the straights where vehicles need to use the full width to negotiate the ramp, however this is considered adequate, as there is full vision for oncoming vehicles. Although the site does not qualify as a domestic property, the basement will only be used by employees and their clients and will not be open to the general public. Rep No. 4284-1 “eM BURCHILL VDM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.