Appendix B - Engineering Plans

of 13

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                  WITH AS3600 EXCEPT WHERE APPROVED BY THE                  OBTAINED FROM WORKSHOP DRAWINGS PRIOR TO                           14.   ALL REINFORCING BARS SHALL BE GRADE N CONFORMING
FOOTINGS AND SLAB ON GROUND                                  STRUCTURAL ENGINEER. NO RE-BENDING SHALL BE               SCHEDULING OF REINFORCEMENT, AND ARE NOT TO EXCEED                            WITH THE REQUIREMENTS OF AS1302
                                                             PERMITTED UNLESS APPROVED BY THE STRUCTURAL               DIMENSIONS WHERE SHOWN ON STRUCTURAL DRAWINGS.
1.   ALL WORKMANSHIP AND MATERIALS SHALL BE IN
                                                             ENGINEER.                                                                                                                         15. WORKMANSHIP INVOLVED IN PLACING CONCRETE
ACCORDANCE WITH THE REQUIREMENTS OF THE RELEVANT
                                                                                                                       20. DO NOT CUT REINFORCEMENT ON SITE TO CLEAR                           MASONRY UNITS SHALL COMPLY WITH AS3700.                  LINDSAY CONSULTING PTY
CURRENT AUSTRALIAN STANDARD CODES,   BUILDING BY-LAWS                                                                                                                                                                                                                      LTD
                                                             8.    ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN    PENETRATIONS. DISPLACE REINFORCEMENT SLIGHTLY AS
AND THE ORDINANCES OF THE   RELEVANT LOCAL AUTHORITY.
                                                             ITS CORRECT POSITION DURING CONCRETING BY APPROVED
                                                             PLASTIC BAR CHAIRS U.N.O.
                                                                                                                       NECESSARY.
                                                                                                                                                                                               CHEMICAL AND MECHANICAL
2.   SLAB ON GROUND TO BE POURED ON WATERPROOF
MEMBRANE AND PLACED ON 50mm BEDDING SAND. MEMBRANE
                                                                                                                       21.  NO CHASES, HOLES GREATER THAN 150mm DIAMETER, OR                   ANCHORS
                                                                 MAXIMUM CENTRES OF SUPPORTING CHAIRS SHALL BE              EMBEDMENT OF PIPES GREATER THAN 40mm DIAMETER
JOINTS TO BE TAPED.
                                                             600mm FOR FABRIC, 600mm FOR BARS UP TO 12mm DIAMETER,     OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS                       1.   "CHEMSET" DENOTES RAMSET GRADE 5.8 HOT DIPPED
                                                             900mm FOR BARS 16mm AND GREATER.                          SHALL BE MADE IN THE CONCRETE SLABS. FOR ALL OTHER                      GALV. STUDS FIXED WITH RAMSET CHEMSET REO 502   WITH
3.   WHERE SAND BED IS REQUIRED UNDER SLAB, THIS SHALL
                                                                                                                       CONCRETE MEMBERS NO PENETRATIONS, CHASES OR                             THE FOLLOWING MINIMUM EMBEDMENTS:
     BE COMPACTED SUFFICIENTLY TO SUPPORT
                                                             9.  ALL OPENINGS AND RE-ENTRANT CORNERS IN THE            EMBEDMENTS SHALL BE MADE WITHOUT PRIOR APPROVAL BY
REINFORCEMENT PLUS 100 kg/CHAIR WITHOUT    VERTICAL
                                                             CONCRETE SHALL HAVE 3-N12 BARS x 2000 LONG TOP AND        THE STRUCTURAL ENGINEER.                                                      M12 CHEMSETS - 110mm EMBEDMENT U.N.O.
DISPLACEMENT EXCEEDING 5mm.
                                                             BOTTOM, CENTRED DIAGONALLY ACROSS THE CORNER.                                                                                           M16 CHEMSETS - 125mm EMBEDMENT U.N.O.
                                                                                                                       22. CONDUITS CAST INTO CONCRETE MEMBERS SHALL BE                              M20 CHEMSETS - 150mm EMBEDMENT U.N.O.
4.   REFER ARCHITECT FOR STEPS AND SETOUT OF ALL SLABS.
                                                             10.   REINFORCEMENT LAPS SHALL BE AS FOLLOWS:-            SPACED AT MAXIMUM DISTANCE POSSIBLE AND UNDER NO                              M24 CHEMSETS - 160mm EMBEDMENT U.N.O.
                                                                                                                       CIRCUMSTANCES CLOSER THAN A CLEAR SPACING OF   TWICE
5.   MINIMUM CONCRETE STRENGTHS IN ACCORDANCE WOITH
                                                                   12mm     500 mm                                     THE LARGER CONDUIT DIAMETER FROM PARALLEL                               2.  "CHEMSET MAXIMA CAPSULES" DENOTES RAMSET
AS3600 TO SUIT APPROPRIATE CONCRETE EXPOSURE
                                                                   16mm     700 mm                                     REINFORCEMENT OR ANY OTHER CONDUIT.                                     CHEMSET MAXIMA SPIN CAPSULES WITH STUDS AND
CLASSIFICATION
                                                                   20mm     900 mm                                                                                                             EMBEDMENTS AS DEFINED IN NOTE 1.
                                                                   24mm     1000 mm                                    23. ALL SAW JOINTS SHALL BE CARRIED OUT WITHIN 8 HRS OF
                                                                   28mm     1200 mm                                        POURING OF SLABS USING A "SOFT CUT" SAW OR SIMILAR.                 3.   "TRUBOLTS" DENOTES RAMSET TRUBOLT HOT DIPPED
6.   MINIMUM LAPS AND SPLICES FOR REINFORCEMENT
                                                                   32mm     1400 mm                                        THE TIME SHALL BE REDUCED TO 4 HRS WHERE THE AIR                    GALV. STUD ANCHORS WITH THE FOLLOWING MINIMUM
                                                                                                                       TEMPERATURE EXCEEDS 32 DEGREES ON THE DAY OF THE POUR                   EMBEDMENTS:
     (A)    SLAB FABRIC - 225 MINIMUM OVERLAP OF
                                                                  FOR ALL OTHER REINFORCEMENT SIZES REFER TO
            TRANSVERSE BARS AT ALL EDGES
                                                             ENGINEER
                                                                                                                       REINFORCED MASONRY                                                            M12 TRUBOLTS - 80mm EMBEDMENT U.N.O.
                                                                                                                                                                                                     M16 TRUBOLTS - 110mm EMBEDMENT U.N.O.
     (B)    TRENCH MESH - 500 SPLICES IN ALL FOOTING BEAMS
-           LAPS AT INTERSECTIONS AS PER THE DRAWINGS        CONCRETE                                                  1.  ALL CONCRETE MASONRY UNITS SHALL CONFORM TO THE
                                                                                                                                                                                                     M20 TRUBOLTS - 135mm EMBEDMENT U.N.O
                                                                                                                       REQUIREMENTS OF AS4456.4 & 10, F'UC= 15 MPA.
     (C)    REINFORCING - 500 SPLICES IN ALL FOOTING BEAMS   1.    CONCRETE WORK SHALL BE IN ACCORDANCE WITH                                                                                   4.   "CHEMSET 101 ANCHORS" DENOTES RAMSET GRADE 5.8
                                                                   AS3600-2018.                                          UNIT       UNIT              REIN.   MORTAR      SALT DURABILTY OF    HOT DIPPED GALV. STUDS, FIXED WITH AN EFFECTIVEDEPTH
            BARS - PROVIDE "L" BARS AT ALL BEAM INTER-
                                                                                                                       LOCATION    STRENGTH   COVER   TYPE    RESIST.         BUILT IN COMP.   OF 64mm INTO EXTRUDED BRICK OR HOLLOW CONCRETE
            SECTIONS WITH 500 LAPS TO EACH LEG
                                                             2.    CONSTRUCTION JOINTS SHALL BE PROPERLY FORMED AND                                                                            BLOCK, USING THE MANUFACTURER'S LEEVES/SIEVES AND
                                                                                                                       BELOW DPC      15        30     M4     EXPOSED          R4
7.   REINFORCEMENT LAPS SHALL BE AS FOLLOWS:-                      USED ONLY WHERE SHOWN OR SPECIFICALLY APPROVED                                                                              RAMSET CHEMSET INJECTION 101.
                                                                   BY THE ENGINEER.                                    EXTERNAL

     12mm        500 mm
                                                                                                                       ABOVE DPC      15        30    M3      EXPOSED          R3              5.  ALL ANCHORS ARE TO BE FIXED IN ACCORDANCE
     16mm        700 mm                                      3.   DO NOT SCALE STRUCTURAL DRAWINGS TO OBTAIN                                                                                       WITH THE MANUFACTURER'S WRITTEN
                                                                                                                       INTERNAL
     20mm        900 mm                                      DIMENSIONS.                                               ABOVE DPC      15        15    M3      PROTECTED        R3
                                                                                                                                                                                               RECOMMENDATIONS.
     24mm        1000 mm
     28mm        1200 mm                                     4.    REFER ARCHITECT FOR SETOUT DIMENSIONS.                                                                                      6.  REINFORCEMENT BARS FIXED INTO CONCRETE USING
     32mm        1400 mm                                                                                               2.   MORTAR SHALL COMFORM TO THE REQUIREMENTS OF                        RAMSET CHEMSET REO 502 EPOXY ARE TO HAVE THE
                                                             5.    MAXIMUM AGGREGATE SIZE SHALL BE 20 mm               AS3700.                                                                 FOLLOWING MINIMUM EMBEDMENTS:
     FOR ALL OTHER REINFORCEMENT SIZES REFER TO
ENGINEER                                                     6.   THE SLUMP OF THE CONCRETE SHALL BE 80 mm PLUS OR     3.   GROUT SHALL BE CONCRETE WITH CHARACTERISTIC                              N12 (500 MPa) BARS - 110mm EMBEDMENT U.N.O.
                                                             MINUS 10 mm                                               STRENGTH AT 28 DAYS (F'C) OF 25 MPA AND A SLUMP OF 250 MM                     N16 (500 MPa) BARS - 125mm EMBEDMENT U.N.O.
8.  BAR CHAIRS SHALL BE PROVIDED AT SPACING IN                                                                         WITH A POURABLE CONSISTENCY.                                                  N20 (500 MPa) BARS - 175mm EMBEDMENT U.N.O.
ACCORDANCE WITH THE RELEVANT STANDARD                        5.   MINIMUM CONCRETE STRENGTHS IN ACCORDANCE WITH                                                                                      N24 (500 MPa) BARS - 400mm EMBEDMENT U.N.O.
                                                             AS3600 TO SUIT APPROPRIATE CONCRETE EXPOSURE              4.    MAXIMUM AGGREGATE SIZE SHALL BE 6 MM.
9.  CURING ON CONCRETE SHALL BE CARRIED OUT IN               CLASSIFICATION                                                                                                                        N GRADE BAR DIAMETERS GREATER THAN THE ABOVE ARE
ACCORDANCE WITH AS3600                                                                                                 5.   CONTRACTOR SHALL ACCURATELY POSITION VERTICAL                          TO BE REFERRED TO THE STRUCTURAL ENGINEER FOR
                                                             6.    ALL CONCRETE SHALL BE VIBRATED.                     REINFORCEMENT TO PROVIDE THE COVER INDICATED ON                         ASSESSMENT.
10   ALL CONCRETE SHALL BE MECHANICALLY VIBRATED IN                                                                    THE DRAWINGS, OTHERWISE THERE SHALL BE A MINIMUM
PLACE.                                                       7.   ALL CONCRETE SHALL BE CURED IN ACCORDANCE WITH       OF 5 MM COVER OF GROUT AROUND ALL REINFORCEMENT.                            MINIMUM EDGE DISTANCE FOR ALL EPOXY BARS TO BE
                                                             AS3600                                                                                                                            150mm.
                                                                                                                       6.    SECURE VERTICAL BARS IN POSITION PRIOR TO PLACING
REINFORCEMENT                                                8.  ALL CONCRETE SHALL BE SAMPLED AND TESTED IN                 CONCRETE OR GROUT.
                                                             ACCORDANCE WITH AS3600 AND AS1379.
1.   REINFORCEMENT IS TO BE IN ACCORDANCE WITH THE                                                                     7.  ALL CONCRETE BLOCKS SHALL BE LAID WITH FACE SHELL
AS/NZS4671 AND TO BE FIXED AS SHOWN ON THE DRAWINGS.                                                                       BEDDING REBATED FLUSH ENDED BLOCKS SHALL BE LAID
                                                             11   THE CONTRACTOR IS TO NOTIFY THE STRUCTURAL
                                                             ENGINEER IN WRITING OF ANY ADMIXTURES TO BE USED IN           WITH ALTERNATE COURSES INVERTED TO PROVIDE
2.  REINFORCEMENT GRADES ARE INDICATED BY THE                                                                          COVER TO HORIZONTAL REINFORCEMENT WHICH SHALL BE
                                                             THE CONCRETE MIX.
FOLLOWING SYMBOLS:                                                                                                     SUPPORTED 20 MM CLEAR OF WEBS. NO MORTAR FINS SHALL
         N-    HOT ROLLED RIBBED REBAR (500 MPa)                                                                       PROTUDE INTO THE GROUT SPACE.
                                                                 NO ADMIXTURES SHALL BE USED WITHOUT WRITTEN
         R-    HOT ROLLED PLAIN ROUND (250 MPa)
                                                             APPROVAL BY THE STRUCTURAL ENGINEER.
         SL - SQUARE MESH                                                                                              8.  CLEAROUTS SHALL BE PROVIDED FOR EACH POUR BY USE
         RL - RECTANGULAR MESH                                                                                             OF PROPRIETARY CLEAN OUT BLOCKS OR UNFILLED
                                                             12. UNLESS NOTED OTHERWISE ALL FORMED EDGES AND
         TM - TRENCH MESH                                    CORNERS OF CONCRETE MEMBERS SHALL HAVE 20mm               MORTAR JOINTS AT THE BOTTOM OF EACH SECTION TO BE
                                                             CHAMFERS.                                                 GROUTED. DURING THE WORK, MORTAR FINS AND ANY OTHER
      THE BAR SIZE IS INDICATED BY A NUMBER AFTER THE                                                                  MATERIAL SHALL BE REMOVED FROM THE GROUT SPACE. THE
ABOVE SYMBOL, WHICH INDICATES THE BAR DIAMETER IN                                                                      CLEAROUT SHALL BE SEALED AFTER   INSPECTION AND
                                                             13. DRIP GROOVES ARE TO BE PROVIDED AT ALL EXPOSED
MILLIMETRES.                                                                                                           BEFORE GROUTING.
                                                             EDGES. COVER TO REINFORCEMENT TO BE MAINTAINED.
3.   COVER TO BE MAINTAINED DURING POURING BY USE OF                                                                   9.    BLOCKWORK SHALL CURE AT LEAST THREE DAYS TO GAIN
                                                             14. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY
PLASTIC TIPPED METAL CHAIRS, PLASTIC CHAIRS AND/OR                                                                           STRENGTH BEFORE POURING GROUT.
                                                             AND NOT NECESSARILY SHOWN IN TRUE PROJECTION.
MORTAR BLOCKS.
                                                             15.  SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE            10.   GROUT SHALL BE PLACED BY PUMPING OR BY ANOTHER
4.   COVER SHALL BE AS SPECIFIED ELSEWHERE . CHAIRING                                                                  APPROVED METHOD AND SHALL BE PLACED BEFORE ANY
                                                             THICKNESS OF APPLIED FINISHES. FALLS TO UPPER
SHALL BE SPACED SUCH THAT THE FOLLOWING TOLERANCES           SURFACES OF SLABS TO BE IN ADDITION TO SLAB THICKNESS.    INITIAL SET OCCURS AND IN NO CASE MORE THAN 1-1/2 HOURS
ARE ACHIEVED DURING                                                                                                    AFTER WATER IS ADDED.
     CONCRETE POUR :                                         16.  BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB
                                                             THICKNESS.                                                11.   GROUTING SHALL BE DONE IN A CONTINUOUS POUR IN
            ABOVE GROUND -      +10 mm/-5 mm                                                                           LIFTS NOT EXCEEDING 1800 MM.
            BELOW GROUND -      +40 mm/-20 mm                17.  CAMBER -UNLESS NOTED OTHERWISE ON DRAWINGS,
                                                             SLABS SHALL BE GIVEN A POSITIVE UPWARD CAMBER AT          12.   AFTER A WAITING PERIOD SUFFICIENT TO PERMIT THE
5.  UNLESS NOTE D OTHERWISE SPLICES IN REINFORCEMENT         MIDSPAN 0F 3MM PER 1000mm SPAN. METHOD OF CAMBERING IS    GROUT TO BECOME PLASTIC BUT BEFORE IT HAS TAKEN ANY
     SHALL BE MADE ONLY IN THE POSITION SHOWN. WRITTEN       TO BE AGREED WITH THE ENGINEER. BEAMS SHALL BE            SET, THE SUCCEEDING LIFT SHALL      BE POURED AND
     APPROVAL BY THE STRUCTURAL ENGINEER SHALL BE            CAMBERED AS SHOWN ON DRAWINGS (NEGATIVE CAMBER IS         VIBRATED WITH THE VIBRATOR EXTENDING 450 mm INTO THE
OBTAINED FOR ANY OTHER SPLICES.                              NOT ALLOWED).                                             PRECEDING LIFT.

6.   WELDING OF REINFORCEMENT WILL BE PERMITTED              18.   CALCIUM CHLORIDE IS NOT PERMITTED TO BE USED.       13.  THE TOP LIFT SHALL BE RECONSOLIDATED AFTER A
ONLY AFTER APPROVAL BY THE STRUCTURAL ENGINEER.                                                                        WAITING PERIOD AND ANY SPACE LEFT BY SHRINKAGE SHALL
                                                             19    EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE   BE REFILLED WITH GROUT.
7.   REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE
Log in to download the original file

Appendix B - Engineering Plans.pdf · 4.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.