representative of Tectonic stating that the use of a rubble pit for ‘overflow’ is acceptable with respect
to the Proposed Unit Development report (24265-001-Rev0).

RECOR RESPONSE:

The plans have been revised to remove the garden beds and associated “rubble pits”. Additionally,
the detention tanks design, which will be utilized for rainwater harvesting, has been updated to
discharge to the south, connecting to the existing infrastructure as shown in the submitted plans.

Furthermore, an additional overflow pipe has been incorporated, which shall be discharged to the
east, daylighting into the proposed batter at the rear of the development. Provisions have also been
made for a swale running the length of the existing retaining wall to ensure effective stormwater
management.

Issue – Temporary and Permanent Retaining Structures


SCCE’s Earthworks Layout Plan (C0202, Rev. B) and associated sections dated 22 November 2024
details excavations adjacent to the site boundary with depths up to 7m. No details of any proposed
temporary or permanent shoring or retaining structures have been documented. Any temporary or
permanent retaining structures must be designed and constructed in accordance with the
recommendations contained in section 6 of Tectonic’s Proposed Unit Development report (24265-
001-Rev0) dated 30 September 2024.

Information Required

Provide details of any proposed retaining structures including temporary and permanent
piling. The detail must be prepared by a suitably qualified person

RECOR RESPONSE:

The earthworks design has been updated to incorporate the proposed locations of concrete piles,
which will serve as structural support for the basement. Please note that both the shoring system
(temporary works) and the detailed structural design shall be fully addressed as part of the building
permit applications. These designs shall ensure compliance with all relevant regulatory requirements
and engineering standards. Furthermore, all proposed works shall be confined within the designated
site boundaries to prevent encroachments and ensure alignment with approved development
parameters.



6
Log in to download the original file

RFI -Civil Technical Memorandum.pdf · 209 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.