Council archive · source document
Decision Notice - 010.2007.00001010.001 [As Published] · 132007.1010
NOOSA COUNCIL IDAS Development Application Decision Notice 4 of 10
14. The developer must obtain all of the other Development Permits referred to in the Decision Notice, prior to
obtaining a Development Permit for Building Works.
Land Development
Vehicle Access
15. A vehicular access driveway to serve the development shall be constructed from the Kingfisher Drive
frontage of the site with a maximum width of 3.5m.
16. The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any step or level difference. Should any driveways be constructed to grades that do not comply
with AS2890.1-2004 Council will require that the driveway be removed and reconstructed to levels that do
comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
17. To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath, the
driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
line requirements as defined in AS2890.1, section 3.2.4. The applicant shall demonstrate compliance by
illustrating these sight lines on the plans submitted for both Operational Works approval and Building
Works approval.
18. All vehicles shall enter and leave the site in a forward direction.
Car Parking
19. Carparking shall be provided within the site as shown on drawing number WD.201 dated Dec 06 by Kidd
& Co. except as modified herein.
20. A minimum of 4 covered carpark spaces shall be provided on site.
21. The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for user class 1A
with allowance for vehicles to enter and leave the site in a forward gear and with a minimum head
clearance (headroom) at any point of 2.2m.
22. All carparking shall be kept, maintained and line-marked in a condition fit for use.
Frontage Works
23. Footpath improvements such as topsoiling, grassing, and tree planting are required to the Kingfisher Drive
frontage of the site in accordance with Planning Scheme Policy PSP03 Landscaping Plants & Guidelines.
Grass shall be couch, free of weeds.
24. Any damage to Council’s existing concrete path shall be repaired or replaced in accordance with Council’s
design standards.
25. All paths, driveways and parking areas shall be designed and constructed to ensure pedestrian safety
using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the
Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility.
26. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
27. Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank (minimum
storage 3000 litres per attached dwelling) that is installed to ensure water from the tank is used for
external uses (such as watering gardens, irrigation, ornamental ponds, water features, topping-up
swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to the dwelling. All
rainwater tanks are to be designed and installed in accordance with the Queensland Development Code
(QDC), Part 25 – Rainwater Tanks, and shall be part of the plumbing application in conjunction with the
building approval. The location and capacity of the tanks shall be clearly shown on the plans submitted
for Building Works and Operational Works approval and any overflow shall be directed to the road
frontage located at Kingfisher Drive.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@40072611\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2007.00001010.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 48 KB (small file)
- File type
No other editions are linked here.