Council archive · source document
Changes Application - MCU15/0023.02
Very large file (15.8 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Project No. 112-14608
January, 2013 REF: 1-14608, 2013-01-15, BR VER O. Page 9
Depressions formed by the removal of vegetation, underground elements etc. should
have all disturbed weakened soil cleaned out and be backfilled with compacted
select material.
The insitu soils, where free of organic and deleterious material, may be used for
structural fill provided the moisture content of the soils on placement approximates
the optimum moisture content required for compaction. This may require
conditioning to bring the soils to optimum.
Imported select fill material, if required, should be a good quality select fill material
with a soaked CBR >10% and a maximum aggregate size of 75mm.
Fill placed in the area of the building should be compacted in layers (approximately
200mm loose thickness) to a density not less than 95% of maximum dry density in
accordance with AS 1289 5.1.1 (Standard Compaction).
Field density testing should be carried out to check the standard of compaction
achieved and the placement moisture content. The frequency and extent of testing
should be as per guidelines in AS.3798-2011, Section 8.0.
The soils encountered on site (to borehole depth) should be within the excavation
limits of a small dozer (eg. Cat D4 or similar) in bulk earthworks and a medium sized
backhoe (eg. Case 580 or similar) in trench excavations.
4.3 Excavation Stability
The following general recommendations are made for short term stability of batters for
bulk excavation of the site.
• Batter angle not greater than 1V:2H above the horizontal.
• Top of batter to be a minimum of 2.0m inside any boundary line, in addition to 3.0
metres distance from any building or structure.
• If batters are to be left untreated for any length of time, a batter angle of 1V:3H is
recommended and berm width are to be strictly maintained.
:#. SOIL SURVEYS ENGINEERING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Changes Application - MCU15/0023.02Related documentApplication case desk ↗
About this file
- File size
- 15.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.