Attached to the e-mail Multiple Housing Type 3 - Retirement & Special Needs (Aged Care Facility (Traffic Report Part 2 & Noise Assessment Report) - MCU18/0019.
Aged Care Facility, Noosaville
Category 2. Standard construction, except for lightweight elements such as fibrous cement
or metal cladding or all-glass facades. Windows, doors and other openings must be closed.
TNR of approximately 25 dB(A) is expected.
Category 3. Special construction, chosen in accordance with Clause 3.4. Windows, doors
and other openings must be closed. TNR between 25 and 35 dB(A) is expected.
Category 4. TNR greater than 35 dB(A) is required; special acoustic advice should be
sought.
2.3 Mechanical Plant
The Environmental Protection Act 1994 specifies criteria for pumps and air
conditioning plant as follows:
440T Pumps
(1) This section applies to premises at or for which there is a pump.
(2) An occupier of the premises must not use, or permit the use of, the pump on
any day—
(a) before 7a.m, if it makes an audible noise; or
(b) from 7a.m. to 7p.m, if it makes a noise of more than 5dB(A) above the
background level; or
(c) from 7p.m. to 10p.m, if it makes a noise of more than 3dB(A) above the
background level; or
(d) after 10p.m, if it makes an audible noise.
(3) Subsection (2)(a), (c) and (d) do not apply to a noise made at an educational
institution, that is not more than 5dB(A) above the background level.
(4) In this section— Pump —
(a) means an electrical, mechanical or pneumatic pump; and
Examples — liquid pump, air pump, heat pump
(b) includes a swimming pool pump and a spa blower.
440U Air-conditioning equipment
(1) This section applies to premises at or for which there is air-conditioning
equipment.
(2) An occupier of the premises must not use, or permit the use of, the equipment
on any day—
(a) before 7a.m, if it makes a noise of more than 3dB(A) above the
background level; or
(b) from 7a.m. to 10p.m, if it makes a noise of more than 5dB(A) above the
background level; or
(c) after 10p.m, if it makes a noise of more than 3dB(A) above the
background level.
These criteria are applicable for noise impacting on, and produced by, the
proposed development.
440V Refrigeration equipment
(1) This section applies to a person who is—
(a) an occupier of premises at or for which there is plant or equipment for
refrigeration (refrigeration equipment); or
(b) an owner of refrigeration equipment that is on or in a vehicle, other than
a vehicle used or to be used on a railway.
1121R1-R0 13 December 2017 Page 3 of 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Noise Assessment Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.