Noise Assessment Report · MCU18/0019

Attached to the e-mail Multiple Housing Type 3 - Retirement & Special Needs (Aged Care Facility (Traffic Report Part 2 & Noise Assessment Report) - MCU18/0019.

of 21

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Aged Care Facility, Noosaville


                     (2) The person must not use, or permit the use of, the refrigeration equipment on
                     any day—
                                 (a) before 7a.m, if it makes a noise of more than 3dB(A) above the
                                 background level; or
                                 (b) from 7a.m. to 10p.m, if it makes a noise of more than 5dB(A) above the
                                 background level; or
                                 (c) after 10p.m, if it makes a noise of more than 3dB(A) above the
                                 background level.
                     (3) In this section—
                     vehicle includes a trailer.


3 Measurements

                     Noise measurements were carried out at the site from 28th November 2017 to 1st
                     December 2017 at the location shown in Figure 3.
                     The measurements were carried out using a Rion NL-21 (serial no. 954584)
                     recording “fast” response A-weighted sound levels at 1-hour intervals, with the
                     microphone at a height of approximately 1.5 m. Weather conditions were
                     generally fine and suitable for noise monitoring for the duration of the survey. The
                     instrument was checked for calibration prior to and post-measurement using a
                     94 dB acoustic signal at 1000 Hz, and drift in calibration remained within ±0.5 dB.
                     The site was attended for a 15-minute period on 1st December 2017 to gain a
                     subjective assessment of the acoustic environment and to verify that the sound
                     measurement instrumentation was functioning correctly.
                     Notes from the attended measurements are provided in Table 2, and a summary
                     of the logged data over the week is provided in Table 3 and Table 4. The
                     measurement data is provided in Appendix B.




                     Figure 3:       Noise Logger Location – Goodchap Street, Noosaville

1121R1-R0                                                 13 December 2017                                    Page 4 of 10

Used in these records

About this file

File size
3.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Noise Assessment Report.pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.