200 SERIES BLOCKWORK 200 SERIES 'H' BLOCKWORK
20MPa COREFILL. 20MPa COREFILL. WATERPROOFING
1/N12 IN A CONTINUOUS WATERPROOFING MEMBRANE IS TO BE APPLIED AND CERTIFIED BY
BOND BEAM A SPECIALIST WATERPROOFING CONTRACTOR ENGAGED BY THE BUILDER. THE
'H' 3000 MAXIMUM HIGH
WATERPROOFING SYSTEM IS TO INCLUDE ALL SLAB AND WALL
GEOFABRIC SEALANTS/WATERSTOPS AS REQUIRED. REFER ARCHITECT FOR FURTHER DETAILS.
1/N12 IN BOND BEAM
FREE DRAINING MATERIAL
WATERPROOFING 10mm CRUSHED ROCK DRAINAGE FILL MATERIAL PLACED AROUND THE DRAINAGE
N12-400 HORIZONTAL N12-400 HORIZONTAL BARS PIPE FOR A MINIMUM OF 300mm AND EXTENDING UP THE BACK OF THE WALL.
55 COVER
BARS (LAP 500) '(LAP 650+CORNER BARS)
'H' 1800 HIGH MAXIMUM.
65 COVER
AGI PIPE
'H' 1800 MAXIMUM HIGH
GEOFABRIC FREE DRAINING 100mm DIAMETER SLOTTED PVC AGRICULTURAL PIPE WRAPPED IN GEOTEXTILE
'V' BARS WATERPROOFING MATERIAL 'V' BARS SOCK, LAID TO A MINIMUM GRADE OF 1 IN 100 OVER 15M LENGTH. THE LOW END OF
TEMPORARY SAFE EACH RUN IS TO BE CONNECTED TO A STORMWATER SYSTEM. THE UPPER END OF
BATTER IN EACH RUN IS TO BE BROUGHT TO THE SURFACE AND CAPPED.
FREE DRAINING TEMPORARY SA
ACCORDANCE WITH
MATERIAL BATTER IN
GEOTECHNICAL 55 ACCORDANCE W GEOFABRIC
ADVICE (SHOWN COVER
GEOFABRIC GEOTECHNICAL GEOTEXTILE SEPARATION LAYER BETWEEN DRAINAGE FILL MATERIAL AND
N12 - 650
N16 - 900
'S' BARS INDICATIVELY ONLY)
SL82 FABRIC RETAINED MATERIAL.
N12-650 LAP
N16-900 LAP
ADVICE (SHOWN
65 COVER COMPACTED INDICATIVELY O
CERTIFIED "COMPACTED"
FILL MATERIAL 300 COG FILL MATERIAL TEMPORARY EXCAVATION
50 SAFE TEMPORARY EXCAVATION TO BE BATTERED/BENCHED IN ACCORDANCE WITH
IN ACCORDANCE WITH
50 GEOTECHNICAL ADVICE TEMPORARY SAFE GEOTECHNICAL ENGINEERS RECOMMENDATIONS.
200
200
AGI. PIPE BATTER IN
ACCORDANCE WITH WALL STARTER BARS
GEOTECHNICAL THE POSITION OF THE STARTER BARS TO THE BLOCK WALL IS CRITICAL. CARE MUST
250
250
ADVICE (SHOWN BE TAKEN TO ENSURE THEY ARE ACCURATELY LOCATED BY USING STRING LINES,
INDICATIVELY ONLY) ETC. ADVISE ENGINEER IF BARS ARE OUT OF POSITION BEFORE LAYING BLOCKS.
'D'
N12-300 AGI. PIPE
(LAP 550) N12-400 'S' BARS N12-300
(LAP 550)
'D'
'S' BARS
2/N12 BOTTOM 1/N12
(LAP 550) (LAP 500)
300 KEY WHERE
REQUIRED. REFER 300 KEY WHERE
SCHEDULE 'B' REQUIRED. REFER
SCHEDULE 'B'
RW1 - TYPE 1 DETAIL RW2 - TYPE 1 DETAIL
SCALE 1:20
RW2
SCALE 1:20
SCALE 1:20
RW1 SCHEDULE RW2 SCHEDULE
TYPE H B D 'V' BARS 'S' BARS H1 TYPE H B D 'V' BARS 'S' BARS H1
600 600 - T.B N12-400 N12-400 - 600 600 -
T.B N12-400 N12-400 -
800 600 - .CN12-400 N12-400 - 800 800 - .CN12-400 N12-400 -
1000 800 400 N12-400 N12-400
TYPE 1
1000 700 - N12-400 N12-400 -
TYPE 1
-
1200 850 400 N12-400 N12-400 - 1200 1100 400 N12-400 N12-400 -
1400 1000 400 N12-400 N16-400 - 1400 1300 500 N12-400 N16-400 -
1600 1300 500 N12-400 N16-400 - 1600 1600 500 N12-400 N16-400 -
1800 1450 500 N12-400 N16-400 - 1800 1800 650 N12-400 N16-400 -
C1 ##.##.#### REVISION NAME BRISBANE
DESIGNED: APPROVED:
T: 07 3852 4333 CONSULTANTS: PROJECT: PROPOSED RESIDENTIAL DEVELOPMENT PROJECT NUMBER
CONSULTANTS NAME S24-###
WE S TE R A
GOLD COAST
DRAWN:
T: 07 5571 1599 LOCATION: PROJECT LOCATION
SUNSHINE COAST
SHEET NUMBER
CHECKED:
PART NE RS T: 07 5391 3777
NORTHERN NSW
USE FIGURED DIMENSIONS ONLY. DO NOT SCALE, IF A DISCREPANCY ARISES CHECK WITH THE
PROJECT ENGINEER AND/OR SUPERVISING AUTHORITY. DO NOT WORK FROM REDUCED SCALE
TITLE: RETAINING WALL DETAILS
3.8
.
DATE: STRUCTURAL+CIVIL+ENVIRONMENTAL ENGINEERS DRAWINGS (A1-A3 SIZE PAPER). COPYRIGHT OF ALL DRAWINGS & WORKS EXECUTED FROM
T: 02 6674 8047 THEM IS VESTED IN WESTERA PARTNERS AND USE OF THERE FORE WITHOUT PERMISSION IS
CENTRAL VICTORIA
CLIENT NAME ##
STRICTLY PROHIBITED! IT IS THE BUILDERS RESPONSIBILITY TO ENSURE ALL WORKS ARE
PAGE SIZE: A3 For and on behalf of www.westerapartners.com.au ABN 52 097 417 975
CARRIED OUT WITHCARE AND DUE DILIGENCE TO COMPLY WITH THE CONTRACT DOCUMENTS. CLIENT: REVISION
No. DATE REVISIONS DRN ENG WESTERA PARTNERS PTY. LTD. T: 03 5441 0922
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.