NOTES
This proposed electrical and lighting plan is to be
completed by building owner in collaboration with
the builder using symbols provided. TO BE COMPLETED WITH
The builder and electrical sub-contractor must
ELECTRICAL CONTRACTOR
confirm the proposed meets the requirements of Part
3.12.5, Vol 2 of the NCC - in particular energy
efficiency of artificial lighting - and consult with the
building owner where changes may be required. The
illumination power density of artificial lighting must not NOTES:
exceed the allowance of:
A. 5W/m² in a Class 1 building; and,
B. 4W/m² on a verandah, balcony or the like
attached to a Class 1 building; and,
C. 3W/m² in a Class 10a building associated with a
Class 1 building.
The above allowances may vary for lighting with a
control device per Part 3.12.5.5 (b), Vol 2 of th NCC.
All plumbing fixtures and installations including
pressure limiting devices, hot water systems and dual
flush toilet suites to be WELS rated in accordance with
AS/NZ6400 - 2005, AS3500, and meet compliance with
part MP 4.1 of the Queensland Development Code
(QDC).
• Shower rose and tapware - to be 3 Star WELS
ELECTRICAL PLAN SYMBOLS
Electrical Meter Box
300
SINGLE GPO @ 300
300 POOL POOL
2 DOUBLE GPO @ 300 PUMP PUMP
1100
SINGLE GPO @ 1100
1100
2
DOUBLE GPO @ 1100
500
WP
2 DOUBLE OUTDOOR WEATHER PROOF GPO @ 500
500
WP
SINGLE OUTDOOR WEATHER PROOF GPO @ 500
1500
tv
TELEVISION POINT @ 1500
300
tv
TELEVISION POINT @ 300
1100
tp
TELEPHONE POINT @ 1100
300
tp
TELEPHONE POINT @ 300
300
D
DATA POINT @ 300
1100
D
DATA POINT @ 1100
AC WALL MOUNTED AIR CONDITIONER
EXT EXTRACTION FAN
SMOKE DETECTOR
No. Description Date
A Approval Issue 10/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELECTRICAL PLAN DRH
B
C
Construction Issue A
Construction Issue B
08/10/2021
28/10/2021
049 As indicated
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd - UPPER LEVEL
www.dennishillarchitect.com
D Construction Issue C 11/03/2022
CON.25
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 11/03/2022 2:58:12 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
049_Duplex_27 Grant St Noosa - Construction Issue C.pdfRelated documentApplication case desk ↗
About this file
- File size
- 25.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.