NOTE
Ceiling fans in accordance with Part 3.12.4.3, Vol 2 of the NCC must be                                                                                                                                                                                                                                                                                                                                           TO BE COMPLETED WITH
permanently installed, have a speed control, and serve the whole room. The floor
area that a single fan serves must not exceed:                                                                                                                                                                                                                                                                                                                                                                   ELECTRICAL CONTRACTOR
•     15m² if it has a blade rotation ø of not less than 900mm; and
•     25m² if it has a blade rotation ø of not less than 1200mm.

Natural lighting is in accordance with Section 3.8.4, Vol 2 of the NCC. Windows in
all habitable rooms in this building must have a aggregate light transmitting area of
                                                                                                                                                                                                                                                                                                                                                                                                            NOTES:
not less than 10% of the floor area of each room.

Natural ventilation is in accordance with Section 3.8.5 Vol 2 of the NCC. All
habitable rooms and other rooms occupied by a person for any purpose in this
building have an aggregate opening of more than 5% of the floor area of the
room.



      LIGHTING PLAN SYMBOLS
                   ELECTRICAL METER BOX
                   SWITCH
          2        SWIITCH, 2
          3
                   SWITCH, 3
          4
                   SWITCH, 4
          d
                   SWITCH WITH DIMMER

                   Two-Way SWICTH

         AC        WALL MOUNTED /
                   OUTDOOR AIR
                   CONDITIONER
                   LIGHT, WALL TWIN
                   HALLOGEN SS ( NO LAMP)

                   12W LED SENSOR FLOOD LIGHT

                   RECESSED DOWNLIGHT

                   RECESSED UPLIGHT (deck or tread
                   mounted wall-wash)
                   GARDEN MOUNTED DIRECTIONAL
                   FLOOD LIGHT
        LED        12V LED CUPBOARDS LIGHT

    LED STRIP LED strip lighting to underside of
              overhead cupboards
                   3-in1 (4 lamps)

                   SMOKE DETECTOR


                   WH 4 BLADE 1200mm CEILING FAN


        HWS        HOT WATER SYSTEM


                   LARGE FEATURE PENDANT


                   SMALL FEATURE PENDANT

                   FLUORESCENT LIGHT




                                                                                                                                                                                                                                                                                                                                                        No.                      Description                                         Date
                                                                                                                                                                                                                                                                                                                                                    A              Construction Issue A                                          08/10/2021                  Project number               Scale at A3
                                                                                                                                            Project                                                  Client                                                        Drawing                                                Drawn by
                                              dennishillarchitect                                                                           27 Grant Street,                                         Brown Rooster Pty                                             LIGHTING PLAN -                                        DRH
                                                                                                                                                                                                                                                                                                                                                    B
                                                                                                                                                                                                                                                                                                                                                    C
                                                                                                                                                                                                                                                                                                                                                                   Construction Issue B
                                                                                                                                                                                                                                                                                                                                                                   Construction Issue C
                                                                                                                                                                                                                                                                                                                                                                                                                                 28/10/2021
                                                                                                                                                                                                                                                                                                                                                                                                                                 11/03/2022
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      049                 As indicated
                                    mobile: 0438 20 55 66 | [email protected]                                                   Noosa Heads                                              Ltd                                                           LOWER
                                                  www.dennishillarchitect.com                                                                                                                                                                                                                                                                                                                                                                                                       CON.26
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   11/03/2022 2:58:12 PM

Used in these records

About this file

File size
25.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

049_Duplex_27 Grant St Noosa - Construction Issue C.pdf · 25.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.