NOTE
Ceiling fans in accordance with Part 3.12.4.3, Vol 2 of the NCC must be
permanently installed, have a speed control, and serve the whole room. The floor
                                                                                                                                                                                                                                                                                                                                                                                                                     TO BE COMPLETED WITH
area that a single fan serves must not exceed:
                                                                                                                                                                                                                                                                                                                                                                                                                    ELECTRICAL CONTRACTOR
•      15m² if it has a blade rotation ø of not less than 900mm; and
•      25m² if it has a blade rotation ø of not less than 1200mm.

Natural lighting is in accordance with Section 3.8.4, Vol 2 of the NCC. Windows in
all habitable rooms in this building must have a aggregate light transmitting area of                                                                                                                                                                                                                                                                                                                          NOTES:
not less than 10% of the floor area of each room.

Natural ventilation is in accordance with Section 3.8.5 Vol 2 of the NCC. All
habitable rooms and other rooms occupied by a person for any purpose in this
building have an aggregate opening of more than 5% of the floor area of the
room.




    LIGHTING PLAN SYMBOLS
                 ELECTRICAL METER BOX
                 SWITCH
        2        SWIITCH, 2
        3
                 SWITCH, 3
        4
                 SWITCH, 4
        d
                 SWITCH WITH DIMMER

                 Two-Way SWICTH

       AC        WALL MOUNTED /
                 OUTDOOR AIR
                 CONDITIONER
                 LIGHT, WALL TWIN
                 HALLOGEN SS ( NO LAMP)

                 12W LED SENSOR FLOOD LIGHT

                 RECESSED DOWNLIGHT

                 RECESSED UPLIGHT (deck or tread
                 mounted wall-wash)
                 GARDEN MOUNTED DIRECTIONAL
                 FLOOD LIGHT
      LED        12V LED CUPBOARDS LIGHT

LED STRIP LED strip lighting to underside of
          overhead cupboards
                 3-in1 (4 lamps)

                 SMOKE DETECTOR


                 WH 4 BLADE 1200mm CEILING FAN


     HWS         HOT WATER SYSTEM


                 LARGE FEATURE PENDANT


                 SMALL FEATURE PENDANT

                 FLUORESCENT LIGHT




                                                                                                                                                                                                                                                                                                                                                        No.                      Description                                         Date
                                                                                                                                                                                                                                                                                                                                                    A              Approval Issue                                                10/10/2020                  Project number               Scale at A3
                                                                                                                                            Project                                                  Client                                                        Drawing                                                Drawn by
                                              dennishillarchitect                                                                           27 Grant Street,                                         Brown Rooster Pty                                             LIGHTING PLAN -                                        DRH
                                                                                                                                                                                                                                                                                                                                                    B
                                                                                                                                                                                                                                                                                                                                                    C
                                                                                                                                                                                                                                                                                                                                                                   Construction Issue A
                                                                                                                                                                                                                                                                                                                                                                   Construction Issue B
                                                                                                                                                                                                                                                                                                                                                                                                                                 08/10/2021
                                                                                                                                                                                                                                                                                                                                                                                                                                 28/10/2021
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      049                 As indicated
                                    mobile: 0438 20 55 66 | [email protected]                                                   Noosa Heads                                              Ltd                                                           GROUND
                                                  www.dennishillarchitect.com
                                                                                                                                                                                                                                                                                                                                                    D              Construction Issue C                                          11/03/2022
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    CON.27
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.   11/03/2022 2:58:13 PM

Used in these records

About this file

File size
25.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

049_Duplex_27 Grant St Noosa - Construction Issue C.pdf · 25.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.