Catchpole Building Services:
compliance~assess~table~perigian
Fire Compartmentation
Applicable
‘he whole building can be assessed as one fire compartmen
las it attracts type B construction. However the carpar'
ortion which is required to be sprinkler protected will nee
ito be 120/120/120 FRL fire separated from the balance of th
on sprinklered building otherwise the rest of that buildin:
ill require sprinkler protection.
Commercial precinct
he class 3 buildings and the carpark each will require fir
icompartmentation storey by storey as the buildings attrac
[Type A fire rated construction.
Residential precinct
[The buildings need to be spaced sufficient distance apart so a:
ot to attract fire rating of the openings in the external wall:
lof the opposing fire compartment.
Recommend that the Class 7
arpark be constructed as
separate fire compartment t
hat of the class 5/6 portions
lbove so as not to require}
sprinklers in those classes.
6 m spatial distance between
openings in external walls i
equired. So as not to driv
he need for fire rate
openings.
Fire Resistance Levels
Applicable
able 4 of Specification C1.1
il FRL’s for floor laid directly on the ground.
External loadbearing walls < 18 m from FSF attract a FRL
Commercial Precinct
External non-loadbearing walls < 3 m from a FSF attract
IFRL.
Imasonry.
Internal non loadbearing walls do not attract a FRL.
Internal loadbearing walls and columns are to be concrete o
Mark CATCHPOLE *
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App P.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 9.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.