Council archive · source document
00156B56.001
Very large file (12.1 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Text sections not matched to the original PDF pages. See original document to check page numbers.
‘ TOWN PLANNING REPORT - Ab
a .
ken nicks
Specific Outcomes Probable solutions Proposal
patrons and staff during
business hours with security
gating only activated for
Commerclal Uses outside of
business hours.
4.3.2 Residential Uses Code
Table 14-21 — For All Residential Uses .
Specific Outcomes Probable solutions Proposal
.
Elechicity supply infrastructure \ .
01 The development does not adversely $1.1} No solution provided Complies - The development will
impact on existing or future electricity not negatively impact on existing
supply infrastructure; electrical infrastructure. The site is
not located within 50m of an
AND $2.1 Development for uses electricity substation or under
@ adjacent to or within S0m of an overhead electricity transmission
O2 All uses and works maintain an existing electricity substation lines or within electricity easements.
adequate safe distance from electrical incorporates noise attenuation
infrastructure including substations, measures to mitigate noise ,
overhead powerlines, power poles and impacts;
transformers. AND
$2.2 Buildings and structures
(including swimming pools, sheds,
. tennis courts or outbuildings} are
not constructed under overhead
electricity transmission lines, or
within electricity easements;
AND
$2.3 A minimum separation
distance is maintained from the
electricity transmission line to the
closest boundary of habitable
buildings and child activity areas,
as follows—
a} 20m for transmission lines up
to 132kV;
b) 30m for transmission lines
between 133kV and 275kV:
@ and
” c) 40m for transmission lines
greater than 275kV.
Hot Water Systems
O3 Hot water systems are installed and $3.1 All hot water systems installed | Complies — The building will
operated to support the efficient use of are— implement hot water systems as
natural resources and minimise solar systems; or prescribed by the applicable
consequent pollution such as greenhouse | electric heat pump systems; or probable solution.
gas emissions. natural gas or LPG systems; or
any combination of a}, b) orc).
Water supply and conservation ;
04 On-site water storage is designed and | $4.7 Ifin a designated rainwater Complies - The proposal is
operated to support the efficient use of tank area as identified in Map | of | identified in Map 1 of schedule 8 as
water; Schedule 8, residential uses that being within a rainwater tank area,
qualify as class 1A or 1B structures A rainwater harvesting tank will be
AND under the Building Code of provided in accordance with:
Australia have a rainwater tank or | schedule 8.
O5 On-site water storage is adequate for tanks in accordance with
occupants every day use and fire fighting | Schedule 8.
purposes. AND .
$5.1 Where not in a water service
area a rainwater tank of a .
minimum of 60,000 litres is
provided for each dwelling unit,
June 2007 Material Change of Use for Retail Business Type 2 Shop & Salon and Page 20 of 33
Visitor Accommodation Type 4 Conventional
33 Hastings Street, Noosa HeadsSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156B56.001.pdfRelated documentPublic source context ↗
07/1181 - MCU - Retail Business Type 2 and Visitor Acommodation Type 4 & Demolition - Robert Selkirk [As Published]Related documentApplication case desk ↗
About this file
- File size
- 12.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.