Noosa Plan 2020: Amendment 2
Part 9 Development codes \ 9.4 Works Codes \ 9.4.10 Waste Management Code




Waste storage areas are located so that they are      Waste storage areas are designed and maintained in     The waste storage area servicing Dolphins
convenient and safe to use and to collect from.       accordance with Planning Scheme Policy PSP9 Waste      Backpackers is:
                                                      management.                                               •       Screened from public view
                                                      AO3.2                                                     •       Constructed on hardstand concrete
                                                      Waste storage areas are designed and located so           •       Bunded to contain wash-down water
                                                      they:                                                     •       Drained to sewer with appropriate fall
                                                      (a) are easily accessed and convenient to use;            •       Large enough to manoeuvre, clean and
                                                      (b) have unobstructed access for the collection of                separate bins
                                                            the waste by service vehicles;                      •       Lit for early morning or late afternoon
                                                      (c) without the need for manual handling;                         visibility
                                                      (d) are clear of carparking bays, loading bays and        •       Located away from sensitive boundaries
                                                            similar areas;                                      •       Easily accessible for staff and waste
                                                      (e) are clear of footpaths and pedestrian access;                 contractors
                                                      (f) are capable of being serviced by the collection       •       Open (unroofed) – this is acceptable
                                                            vehicle without impeding traffic flow; and                  because:
                                                      (g) have a level area provided for the storage of                 o the area drains to sewer,
                                                            waste, recyclable materials and green waste in              o is fully bunded, and stores domestic
                                                            standard bins.                                                   waste only, meeting Code
                                                      AO3.3                                                                  requirements
                                                      For uses that do not employ a caretaker or central     A waste Management Plan is provide as
                                                      management, the maximum distance between waste         Appendix E.
                                                      storage areas and the kerbside is 60 metres.
                                                      AO3.4
                                                      Pathways used to transport bins:
                                                      (a) have a maximum grade of 1:15; and
                                                      (b) are free of steps, stairs or other impediments.
PO4                                                   AO4.1
Waste storage areas are designed for ease of          Waste storage areas are constructed of impermeable
maintenance and ease of access for cleaning.          and durable surfaces that are easily cleaned.
                                                      AO4.2
                                                      Sufficient space is provided between and around
                                                      waste storage bins to allow for manoeuvring and
                                                      washing of bins.
PO5                                                   No acceptable outcome provided
Waste storage areas provide a safe and secure
environment for users through:


Print Date: 17/10/2025                                                                                                                                   Page 3

Used in these records

About this file

File size
918 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

App G - Code Tables.pdf · 918 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.