Stage 2 (1) · EXE22/0005
GENERAL NOTES
lot 45 on N21844
24 wesley court, noosa heads 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
03 of 05 AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
elevation B 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
4465
propose jetty BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
800 1995 MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
600
CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
proposed roof over HER OWN WORK
optional aluminium 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
frame + glass roof (or alike) 3660.1.2000
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
3080 950
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
6800
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
existing 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
deck AND INTERCOM SYSTEMS.
3. DEVICES MUST BE INTERCONNECTED AND HARD
existing WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
residence propose remove 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
stairs existing tree BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
propose storage under 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
line of floor over
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
4550
PRIVACY OPTIONS
propose pergola
to extend from ELECTRICAL AND ENERGY EFFICIENCY
existing upper 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
4020
floor cantilever AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
700 350
DN
DOWNPIPES
relocate stairs + propose ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
screen to outdoor shower CONFIRMED AT TIME OF ROOFING CONSTRUCTION
extend wall from existing brickwork + shutters over to propose bbq bench AND COMPLIANCE
1185 1130
elevation A
existing floor
03 of 05
concept drawings only elevation D
not for construction 03 of 05
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: CATHERINE + ROBERT BUILDER: NOOSA OWN MANDY'S DESIGN & DRAFTING SHEET: DATE: ISSUE NO:
EXTENSION + JETTY MARTYR PH: 5474 1906 PH: 0403 481 474 SCALE: 16 SEPT 2021 CR-2021-B
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH