Council archive · source document
00156930.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
3
t [Revison [Descipion Ci
DRAWING SIZE — AS [A [Reiseue pans =i 16
=I |
st | | kK LA pT
VB VB SHR 40V Mott 9/06/2006 4:34 Pw 16115—H1—-H4.deg
——_———6
First Floor he
FWG
FWG
Nae FWG
SK SK ro
— "6,
FWG Ground Floor ‘ioe Genera! Notes :
fu,
1. Hydraulic services shown are diogramatic only. Refer to architectural
VIEL DIDI ELLLLELLLLeLLULELL LEILA LE LLLLLLLLLLLL ELS drowings for locotions of fixtures.
DN VB SK LT CLLZLTZLLIOLLLLL LL BOL EL LL ELLLEL LLL ELM ho 2. All Sanitary Hydraulics and Woter Reticulation within the allotment
@ 100 J boundary to be in accordance with AS3500.
TC Fwo Basement Floor 3. All work shail comply with the requirements of authorities having
prisdiction, after oblaining all necessary permits and approvats.
Le | 4. The contractor is to confirm the position of all existing services os
Lu y indicated on these and associated plans prior to the commencing of
work.
we
5. Stormwater drainage pipes to 225@ shall be Class SW uPVC HEAVY
To vented
{U.N.0.) pipe. Over 2256 Concrete Rubber Ring Joint (RRU) Class 3. All
S STACK DIAGRAM pipes U.N.O. to be laid at o minimum grade of 1 in 100 U.N.O. Joins are
to be constructed in accordance with the monufacturers requirements.
“\ j SHR FWG 6. Sewers 100mm diam. uPVC DWV (U.N.0.) and Jaid at e minimum
grade of 1 in 60.
we 7. Water supply pipework below ground is to be ;
Hot water outlet Cold expansion lL HR 40V 63mm diam. or jess - High Density Type 50
Class 12 Polyethylene
Temperature /Pressure To valve, outlet 8. All above ground and internal water supply pipework to be Type B
limiting valve to drain Copper.
Union Line FIRST FLOOR PLAN 9. Woter services are not permitted in ground slobs and all joins and
strainer connections shall be made above the slab.
Hot water temperature H.W.U, filling “/ Pressure limiting 10. Fire Hydrants are to be installed are to be installed in accordance
sontrol devices in 75 min with AS2419.1. Hose Reels are to be installed in accordance with AS2441.
‘acoord AS3500.4.2 typical valve. 11. Clean-outs, Inspection openings and Closing caps situated in
vehicular or pedestrian pavements are to be fitted with either brass or
20¢ CW Supply
200 HW cast-iron covers.
P<] <->
NE oe | Isolating valve 12. All in-ground valves shall be in accordance in approved concrete
path boxes.
200 CW Non-return 13. All woste pipes and woter services penetrating slabs to be wrapped
heeled valve mount on wall 40 in an approved flexible joint joint wrapping.
q#{_H4t = ae —-—SHR-——-| 48 14. The term "SERVICE’ refers to the minimum internal pipe diometer
ee i re +$— “unless Aoted otherwise. —_—
a ee we 100
Safe trey in accordance with SK 50 CONSULTING ENGINEERS
50¢ sole” AS3500.4 Cl 4.4 - C1 4.5 LT 65 CBE ‘
FWG 65 siructural - civil - geotechnical WS
(cs
ee
Sey
waste. HOT WATER UNIT DETAIL ABN 40 098 481 899
(AS3500.4) 18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY Cal ~ Woter Meier. Ph (07) 5447 5544 Fax (07) 5447 2634
— UPVC Sewer, size grade and invert sec «=~ «=Stormwoter pipe, size, grade and invert
B Bath HCB House Connection Branch NRV Non-Reiurn Valve TG Test Gale level as noted levels os noted
CO Clean-Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V Vent — External Poly Water Service, size as noted Cy ‘he - Cold and Hot Woter riser
DP Rainwater Down-Pipe HWU Hot Woter Unit PLY Pressure Limiting Valve VB Vanity Basin riser locations and size.
FP Frog Flap Inspection Chamber SC Stop Cock Cc Vent Cowl —CWw— - Internal Cold Water service — Sanitary Stack number and Vent size »
FWG Floor Woste Gully 10 Inspection Opening SHR Shower we Woter Closet — Internal Hot Water service —® — Fixture Unit loading. o
HC Hose Cock Laundry Tub SK Sink WM Washing MachineSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.