Fe | _
FIXTURE y pf
7
B y Mott 9/06/2006 4:34 Pu 16115—H1—-H4.d0q
SHR mT 7 y ~ A
I
we 100 | i Tv 7 | y se ee Se
SK | ' x ' y
4 ™
LT 65 VIDLLIPI DEL eezzZLEZPIZIZZZZ) if onc
FWG 65 =- 4
tI
VI
{|
lI SK
General Notes
1. Hydraulic services shown are diagramatic only. Refer to architectural
drawings for focations of fixtures.
t FWG 2. All Sanitary Hydraulics ond Woter Reticulation within the allotment
Hl {| | i O boundary to be in accordance with AS33500
| {| u 3. Alt work shalt comply with the requirements of authorities having
ore ame OEE I IIIIIZT TIE IZILIZITTEN IESE 7) risdiction, after obtaining all necessary permits and approvals.
0 Vid Wg
| |
4. The contractor is to confirm the position of all existing services os
Void vB wey¥ 4 indicated on these and associated plons prior to the commencing of
HI YET Y work.
A
VI
5. Stormwater drainage pipes to 225¢ shall be Closs SW uPVC HEAVY
PZ e leer eee eee /) (U.N.O.) pipe. Over 2254 Concrete Rubber Ring Joint (RRJ) Class 3. All
Y pipes U.N.O. to be laid ct o minimum grade of 1 in 100 U.N.O. Joins are
to be constructed in accordance with the manufacturers requirements
6. Sewers 100mm diam. uPVC DWV (U.N.O.) and taid at a minimum
grade of 1 in 60
7. Water supply pipework below ground is to be
KY SK
VI 63mm diam. or less — High Density Type 50
|| Class 12 Polyethylene
Vt 8. All above ground and internal water supply pipework to be Type B
il Copper.
xamdl - eigen oe FR 9. Water services are not permitted in ground slabs and all joins and
—_— connections shall be made above the slab
10. Fire Hydrants are to be installed are to be installed in accordance
ied , vy with AS2419.1. Hose Reels are to be installed in accordance with AS2441
) 11. Gean-outs, Inspection openings and Closing caps situated in
vehicular or pedestrian pavements are to be fitted with either brass or
y cast-iron covers
l — eas aaa \ | 12. All in-ground valves shall be in accordance in approved concrete
yi path boxes.
13. All waste pipes ond water services penetrating slabs to be wrapped
in an approved flexible joint joint wrapping
14. The term ‘SERVICE’ refers to the minimum internal pipe diometer
— a ee en ee eR -_- — + ed ee ae unless noted otherwise
GROUND FLOOR PLAN DEBUILD T/A CONSULTING aS)
SGGs ENGINEERS £€&
structural - civil - gectechnical SS
SS)
ABN 40 098 481 899
18 DUKE STREET SUNSHINE BEACH OQLD.4567
LEGEND KEY i | — Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
— UPVC Sewer, size grade and invert mcm. ~-— Stormwater pipe, size, grade ond invert Title Internal Hydraulics Arrangement
B Bath HCB House Connection Branch NRV Non-Return Valve TG Test Gate level as noted levels as noted
CO Clean—Out HR 36m Fire Hose Reel ORG Overflow Relief Gully v Vent —"*#— ~ External Poly Water Service, size as noted Sy Hy ~ Cold and Hot Water riser
DP Rainwater Down—Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin riser locations and size.
FP Fr Flap IC Inspection Chamber Sc Stop Cock VC Vent Cowl —cCt¥—~ {internal Cold Water service a - Sanitary Stack number and Vent size x Date: May 2006 | DrgNo.t6115-H2 |" A |
=
FWG Floor Waste Gully 10 Inspection Opening SHR Shower WC Water Closet —& - Fixture Unit loading co
&
HC Hose Cock Laundry Tub SK Sink WM Woshing Machine Internal Hot Water service &See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.