a)
DISCHARGE PIPE SIZE Refer , fe psc as |
16115-H4 for
rixmure | ON | supply, +e e reset teres teen ee aD aE ae Ee yb none berets tisstectitgrts tereserteeges sess HWUs on sofe Refer pf
20 HW
B 40 co mm me es —-wW¥— trays, 50 oe 16115-H4 for Matt 9/06/2006 4:34 Pu 16115—-H1-H4.dwg
waste to FP.
SHR 40 connection
WC 100 E_ eevee seeder eetes seeeeratrtnera ean enahnd Tovvcsssenrervrcessteeetree?
© Th:
SK 50
LT 65
FWG 65 Unit 1 |
-—_— — — =
;
y
7A : FP TT, SL 7. _— a) General Notes
FP LT vBY | | 1. Hydraulic services shown are diagramatic only. Refer to architectural
FWG drawings for locations of fixtures
FWG
2. All Sanitary Hydraulics and Water Reticulation within the allotment
y Pee \ | we wb | boundary to be in accordance with AS3500.
3. All work shall comply with the requirements of authorities having
reer 4 prisdiction, after obtaining all necessary permits and approvals.
CLLLLIIIZZINIZIIL TZ ALLL LIA Zp LL PEDIC | 4. The contractor is to confirm the position of all existing services as
! ‘ \
ey pitts 3 ah work.
4 \ | | AWC Te indicated on these and associated plans prior to the commencing of
phys
io} 5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
FWGE (U.N.0.) pipe. Over 2259 Concrete Rubber Ring Joint (RRU) Class 3. All
I FP. peistersenfeegs "| pipes U.N.O. to be Iaid at @ minimum grode of 1 in 100 U.N.0. doins are
to be constructed in accordance with the manufacturers requirements
of orf 6. Sewers 100mm diam. uPVC DWV (U.N.O.) and Icid at o minimum
VBA
a eG] awe eecsenrananrran es ssnennnnnasseaverey +o grade of 1 in 60.
7. Water supply pipework below ground is to be
63mm diam. or less - High Density Type 50
y Class 12 Polyethylene
8. All above ground and internal water supply pipework to be Type B
Copper.
Terese er erp eee eT eee eae 9. Woter services are not permitted in ground slabs and all joins ond
connections shalt be made above the slab
Unit 2 Loe : 10. Fire Hydrants are to be installed are to be installed in accordance
| with AS2419.1. Hose Reels are to be installed in accordance with AS2441
11. Clean—outs, inspection openings and Closing caps situated in
fa Dees beer sere eter tt tar seee tee ees eees ett sees vehicular or pedestrian pavements are to be fitted with either bross or
20 co CO cast-iron covers.
we me ee ee ee ee eee —-W¥— 12. All in-ground valves shall be in accordance in approved concrete
Refer J 20 HW path boxes
13. All waste pipes ond woter services penetrating slabs to be wrapped
16115-H4 for HWU's on safe in an approved fiexible joint joint wrapping
supply trays, 50 14. The term SERVICE’ refers to_the minimum internal pipe diameter
—- | ——$ — — ~~ = ae ee waste to FP ee unless noted otherwise
SOE
EBUILD TA
BASEMENT FLOOR PLAN sirucigal «evil ENGINEERS \&
Siruciural - - Geoleennical
ABN 40 098 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY Caml — Water Meter Ph (07) 5447 5544 Fax (07) 5447 2634
~ UPVC Sewer, size grade ond invert ames «=~ Stormwater pipe, size, grade and invert
B Bath HCB House Connection Branch NRV Non-Retum Valve 1G Test Gate level as noted levels as noted Title Internal Hydraulics Arrangement
CO Cean-Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V Vent —w— - External Poly Water Service, size as noted Cy he - Cold and Hot Water riser
DP Rainwater Down—Pipe HW Hot Water Unit PLY Pressure Limiting Valve VB Vanity Basin riser locations and size
o-— - Sanitary Stock number and Vent size »
FP Frog Flap IC Inspection Chamber SC Stop Cock VC Vent Cowl — CWw— Internal Cold Water service ~© Peano | Dane wise PA,
FWG Floor Waste Gully 0 Inspection Opening SHR Shower WC Water Closet =
o
a
HC Hose Cock Laundry Tub Sink WM Washing Machine Internal Hot Water service — Fixture Unit loading.
&See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.