DRAWING SIZE - A2
Ir PRIOR TO CONSTRUCTION ENGINEERS EX ER 1426 /2EH 1 TA11S OW erg
HC 1S TO REVEW CONTOUR SERVEY NOTES: ontr
(70 BE PROVIDED) ON BOTH
ile WHERE NO RETAINING THE GARDEN ALOTMENTS IN TO CONFIRM THE 1. Existing footpaths fo be saw cut prior to removol
WALL 6S 10 BE GROUT FRLED 6TH INDICATES SHEET PUNG, DESIGN AND DETAILS CONTAINED HERE IN. 2. Crossings ore not designed for commercid vehicles
N12-1200 CIRS VERT & HORIZ.
Neturol Ground in INSTALLATION SY OTHERS. GURDER 10 CONTIRY 3. Congete driveway to be 125mm thk. exchding any
EXTENT REQUIRED TO SATISFY CRIMCAL DEPTH finished treatments, eg. stomping
iL MIZ 6 400 UNE. PROTECTION OF NEIGHBOURING STRUCTRES 4. Concrete axfoce loferonce +5.0mm over 3.0m
Horizonial & {(MINTWUM VIBRATION TECHNIQUES 10 BE USED. 5, Concrele N25 in occordance with AS 1379 ond AS
Vertical PRE- AUGERING OR BETTER} 3600
oterproo! wall 1s ea tk MANTAS STABUTY 6. Reinforcement fobric to AS 1304, placed central sob
oF s, depth.
fk | 6 | “Ti Es OVE MAY CROSS OVER DETALS RETER CTCAL OGPTH UME 7. Expension joints lo be 10mm wide wet loaled with
Pee every 2nd mesh wire cul long jot.
(max) (nin) TO BE WN ACCORDANCE WITH 8 One occess point permitled for eoch oflotmeni.
1200 600 ; NOOSA SHIRE COUNOL’S SID 4 Ae 9. For curved driveways, maximum grodes opply to inside
DRAWNGS 9005 & 9018. oS acs edge of curve
je 13 =—_— — at = 10. Al services to be located ond prolected os required
— =>.
1500 1000 S182 Wesh flop 40 om os ee eS ———— ee o—
J 903 uPVC SW o SL —— SS
K cover, APPROVED 5.0. eS Se, >» — prior to work commencing
—— — KEPS ADAPTOR. ws 300 UPVC Si ‘0c uPVC SW a1). ’
~-
400 Cog Longitudinal bors OWSON MERE AND CHANNEL, —— tT owe wee UNIT 14
812-400
TO GE CUT AND REMOED af ae
[ H < 1500 ~ NIZ-400 AND NEW ODPME WAY 10 & ie we Sores sree of BY
STALLED 30 WLS.C STANDARDS. W—-03 OTHERS
K ¢ 2000 ~ Ni6-406 ee
ol RI2W top & botto ONG DEPTH ij rt) GRATED. DRAM | = LU 1 N
wa _ _ LS aie RE COMTRACKA 5 1 STALL APPROVED SALT PETENTICN FENCES
R6 figs 450 ctrs FOO PRO? 1 COMMENONG AMY EARTHRORKS. HE FENCE 6 10 &&
NI2 Full 20-4irwa AGCREGATE Rr om 900(} GEO-FABRIC SLT COMSTRUCTED ALONG THE LOEEST BOUNDARY AMD RETURNED UP SE
tength ut2-400 | 1200 | 300 _| HARD STAND OVERLAY UE Fai DRIVEWAY tain aeton raat Se dsrT Existing tember FENCE, FIXED 10 SPIKES AND QOURDARES 90 ENSURE FULL STORMWATER ENTRAPMENT. SURFACE
0 FOR DRIVE WAYS QUREC WP’ {__ retaining wot BURED 300 INTO STABLE RUFF FROM SeTHIN THE ALLOTMENT MUST ORAM IDRARDS THE
| 1600 | 480 _] LOT 1 aN dosane GROUND. FORCE AMO SHALL NOT ENTER MIEGHBOURING ALLOTUENTS THROUGH
ot at O° we? »—_ THE USE OF SURFACE GUMOIRG OR SOUUR PROTECTED ORanTS. THE
- Bose Width {2000 | 450_| EOSTING DRIVE WAY TO Gf ALLL a7 UE RAN sangyreventens annanel aN FORCE MUST ROXAN PS PLACE UN SUCH TRE HAT FSHED
TYPICAL SECTION ~ (RW-03) RETAINING WALL SMASHED AND REMOVED AND Yorn ——— 3 s it 9% OTHERS tll LANDSCAPING AND DRARACE MEASLES ARE STALLED
KERE AND CHANNEL TO GE a
H
RESTATED TO ASC APPROVAL as RW-03: ay | gs " i= IB Hi
{LS =
APPROMED WSC
KERG ADAPTOR. Weed tae eaten eb UNIT 2 =| =I TUT
—_ hey, mt. ort. IEA tt
ww 1508 uPVC SW ne ond TM)? 1200{L} 50 Sq. HDWO SPIKES, i =
ww ah Gwe nF 1800 cirs DRIVE 600 INTO tT =
== GROUND. iT fl
ie en eg ey L{8T} oe” iI i
1509 uPVC SW Sans aneeseeeeenesas -- If +I
ya BN}
a UNIT 4 ie TYPICAL SECTION ~ SILT FENCE
ee
LEGEND G BY
Wi - VSOW) GRATED ORAN OTHERS
R¥-03 Type 3 Retaining wal, refer detois Yj cee: enna pe Ate beens, awe ) Ground / Sain This foating
2 ino* ab
Verity wees See SS nae aes aa! This foating J sithout piers |
GuF Garden Woll Fooling, refer 16115-S1 for detois 240mm ACGRECATE e Wy j FAL LOT 2 yistomrssscs. “PROPOSED: OI er. boat Unstoble Ea=— is founded The buader /contractor
ae
@--- Indicates position of approved sil relension HARD STAND OVERLAY LU % xe ORIVEWAY Peereitiit a! PLEX a isting timber above criticol | sholl confrrn of relevent
FOR ORE BATS DURING
CONSTRUCTION. & depth line ond! levels price to
fence. WO BE O3T AND REWOMED Y LL RW - ISOUW) GRATED ORAM easaeraseeaiaeees! reloining wal founded below Sloble is unstable. I commencing works.
OOSTNG KERB AND CHANFIELL Toe Aas BY crilicd ne ond |—— Line of
sloble,
—™ Indicoles direction of fol to asfoce levels, WO HER ORME BAY 10 gd tees UNIT 2 OTHERS Pies supporting wef t proposed Poot
FAL STALLED 10 WSC STANDARDS. ray — 73 ‘ Excavation or
SJ! other trench,
footings or post pod
{HT cates JO00{Li) under ground holding tank. 1509 uPVC SW as a footings founded into
ws “7 oreracennnnsssennrstensnss (HT) af | seected materia’ ond below 30 Beg
aie QT ns i fo | a. wee | Horizontal
nat ects SS a:
~ ad" c —- ——— oS = triticd Tine ore considered
= oe we sar © « bt stoble.
. -FILLING-NOJES: Doshed fine ndcales INDICATES SHEET PIUNG, DESGN AND CRITICAL DEPTH LINE THs DETAR ASO APPLES 10
—The site is lo be scraped clear of all organic moterial ond debris. EXISTING FOUNDARONS ON
Sob thickness tor WWSTALLATION BY OTHERS. BRELDER 10 CONF IRW NEIGHBOURNG PROPER
|_>_Any_ f@i_is.la_be_cenn_gronuor moterid_{ie_sond_to o_dayey. TENT-REQURED-TO-SATISF Y-CRETICAL DEP PUN TES. SHEET
3 LED crt
in occardonce with ASI726) be free of ony organic moteriot ond have LINE, PROTECTION OF NEIGHBOURING STRUCTRES. QXOSTING FOOTINGS WL BE
© day content of less (hon 12% (Ptosticily indea less thon 25% Lineor (WINIMUM WERATION TECHNIQUES TO SE USED. Loy back Kerb & FOUNDED ABOVE ANY EXCAVATION
shrinkoge of 15%). The proposes moterial is to be inspected by SCG PRE-AUGERING OR BETTER) Chonne! to KSC CRICA, DEPTH UNE
stondord.
Consulling Engineers prict to its removo to ensure Rs compatabiity TO GE WTHIN PROPERTY BOUNDARY LINE, EXISTING MATCH EXSTING
~ The fil is lo be ploced ond campocted in accordance with S82 Meh CROSS FALL o> CROSS FALL Issue:
AS3798-1996 lo a level sufficient to ocheeve o Level 1 certificctlion SITE_PLAN oor. 350 CONSTRUCTION
with o minimum reotive field density of 55% Copies of compoction (Scole t:200) LEE Extend sub-base 150mm SCG
test remdis shall be presenled lo SCG Cansutiing Engineers for CONSULTING ENGINEERS
approvd. = ae va Se LLL LLL LE possed bock af kerb. siuciural - civil - geotechnical
- filing and compocting odjocent exisiling structures is lo be in Pao aap ABN 40 08 481 899
a slrict occordance with the ossocicted detcis and specifcations. Le sf fete ——= Depth determined { Subgrode preperation,
= Areas where exnsling structures or trees ore removed shall be at \ tom 18 DUKE STREET SUNSHINE BEACH QLD.4567
bock/led with the approved fa moterial compocied in occordonce with Ses cot ond BARRER, SEM-MOUMT ARLE. MOUNTABLE sand bed on-site. PAVEMENT MATERIALS tees generd notes. Ph (07) 5447 5544 Fax (07) 5447 2634
AS2870-1596 to achieve 0 minimum selative field densily of 95% bretkout Zim Aspholtic Surfocing to N.S.C specificotions
— Any loose or soft moterid uncovered in the sile preparation shall bock of kerb KERB $ CHANME| OR VERT CROSSING 150 Bose course lye 21 COR 80
be removed and reploced with the opproved fii materiol compocted in 150 Sub-bose course type 2.3 CBR 45
— pecordance with AS2870-1996 to ochieve o mimimum refolive field CROSSOVER DETAIL Sub-grade preperation in occordonce with specificotions /netes
er density of 95% (Scale 1:20) LAY BACK KERB & CHANNEL
eae,
—— — Site drainoge ond s#! protection measures must be insicted prior
to construction commencing.
-—
anne ee eee aren
eeSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.