Council archive · source document
00156930.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
» @
®)
Description
New 25dn Water Service 2/25mm Meters with dud
brench and meter from check valves in individual |
counci# main, by N.S.C. path boxes with unit New HCB (10) po
numbers clearly marked. SI 39.76
RP Boundary Line Ik 38.46 Matt 9/05/2006 4:34 Pi 1611S—Hi—H4.dwg
se eee CS eee Se —_— — —___J
eee ee cece cece pate eee eee reer te Yi on oe es eee er mene
seme 20dn 18dn Existing branch house
Oy, HC ao ee hee on ee re en ee ey ORG coe F Ic I connection line to be BUILDER AND PLUMBER 10
capped and disused
HC CONFIRM ALL CONNECTION
= ><) POOL BY I POINTS FOR SERVICES TO
—_-. OCV OTHERS
|| PROPOSED UNITS PRIOR TO
CONSTRUCTION COMMENCING.
LOT 1 Units 1 & 2
t wo DN40 PUMPED DISCHARGE General Notes :
FROM POOL, CONNECTION 1. Hydraulic services shown are diogramatic only. Refer to architectural
POOL BY TO GULLIES IN ACCORD. drawings for locations of fixtures.
OTHERS AS3500.2.2-1996 CL. 10.9 2. All Sanitery Hydraulics and Water Reticulation within the allotment
_——-—__.. DCV lao boundary to be in accordance with AS3500.
———$—$_{
HC 3. All work shall comply with the requirements of authorities having
HC New HCB (10) prisdiction, after obtaining all necessary permits and approvals.
IL 40.00
41.00 4. The contractor is to confirm the position of all existing services os
Bae eee eam ss eror ems cam some Woe eee 0 LSS cee ee eee ee em 18dn indicated on these and associated plans prior to the commencing of
6 ee ee emer emmes,
20dn iw work.
— ee ee eee ee ee
ferent tre W ee eueeeeeeee Ke) »RP Boundar Line Z| 50% Rising Main 5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
20dn ef iw 18d: ae | pel” (U.N.O.) pipe. Over 2256 Concrete Rubber Ring Joint (RRu) Class 3. All
ae
al HC | * gee | | pipes U.N.O. to be Icid at @ minimum grode of 1 in 100 U.N.O. Joins are
Existing branch house to be constructed in accordance with the manufacturers requirements.
HC connection line ta be 6. Sewers 100mm diam. uPVC DWV (U.N.0.) ond laid ot a minimum
DCV POO. BY capped and disused grade of 1 in 60.
= SO OTHERS
7. Water supply pipework below ground is to be ;
PROVIDE AN APPROVED
PUMP WELL WITH REMOTE 63mm diam. or less — High Density Type 50
a MOUNTED CONTROL PANEL Class 12 Polyethylene
AND WARNING SIGNAL 8. All above ground and internal water supply pipework to be Type B
LOT 1 Units 1 & 2 Copper.
9, Water services are not permitted in ground slabs and all joins and
connections shall be made cbove the stab.
10. Fire Hydrants are to be installed are to be installed in accordance
with AS2419.1. Hose Reels are to be installed in accordance with AS2441,
7 11. Clean-outs, Inspection openings and Closing caps situated in
vehicular or pedestrian pavements ore to be fitted with either brass or
-—————. DCV cast-iron covers.
go" HC 25dn ~~] | | 12. All in-ground valves shail be in accordance in approved concrete
path boxes.
2 Fes er ee ee mE 9 W 18dn 4 13. All waste pipes and woter services penetrating slabs to be wrapped
ee ene} ened ain mcm nr oe in an approved flexible joint joint wrapping.
L_* 20dn a? iw a eee aac a™™OC 14. The term ‘SERVICE’ refers to the minimum internal pipe diometer ew
———}- ——— -~ _——_—_—_—_—__——. i RP Boundary Line —$—$—__ Sewer unless noted otherwise.
—
PRIOR TO CONSTRUCTION ENGINEERS Mon Hole OEBUILD TIA
2/25mm Meters with dual 1S TO REVIEW CONTOUR SERVEY SG CONSULTING ENGINEERS
path boxes with unit SITE PLAN (TO BE PROVIDED) ON BOTH sirucwusal - Givi - Gectechnica
New 25dn Water Service check volves in individual ALOTWENTS WN TO CONFIRN THE !
branch ond meter from DETAILS CONTAINED HERE IN.
ABN 40 998 481 899
council main, by N.S.C. numbers clearly marked. (Scale 1: 200)
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY Cee - Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
DCV Dual Check Volue Non—Return Valve TG Test Gate ~ UPVC Sewer, size grade and invert zemcex ~4~ Stormwater pipe, size, grade and invert Title: Internal Hydraulics Arrangement
B Bath HCB House Connection Branch NRV level as noted levels as noted
CO Cean-Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V Vent —wW¥— - External Poly Water Service, size as noted °y he — Cold and Hot Waiter riser Project Lot 161 Orealla Cres
DP Rainwater Down-Pipe HW Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin riser locations and size.
FP Frog Flap { Inspection Chamber Sc Stop Cock VC Vent Cowl —cw— — Internal Coid Water service Gy - Sanitary Stock number and Vent size g Sunrise Beach
FWG Floor Waste Gully Id Inspection Opening SHR Shower WC Water Closet ~@ =
HC Hose Cock LT Laundry Tub SK Sink WM Washing Machine —HW— — Internal Hot Water service — Fixture Unit loading.See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.