Maintenance Procedures To ensure optimal performance, it is advisable that regular maintenance is performed. Typically the Jellyfish® requires a service every 6 months, additionally as the Jellyfish® cartridges capture pollutants they will need to be replaced (expected cartridge life is 2-5 years with a maximum cartridge life of 5 years). Primary types of maintenance The table below outlines the primary types of maintenance activities that typically take place as part of an ongoing maintenance schedule for the Jellyfish®. Service Type Description of Typical Activities ecclol ag Removal & rinsing of cartridges . . Wash down of deck level Minor Service Removal of large floatable pollutants Removal of accumulated sediment (if required) Every 6 Months Major Service Replacement of Jellyfish® cartridges As required Maintenance requirements and frequencies are dependent on the pollutant load characteristics of each site. The frequencies provided in this document represent what the manufacturer considers to be best practice to ensure the continuing operation of the device is in line with the original design specification. Minor Service This service is designed to assess the condition of the Rinse each tentacle individually - NOTE: excessive Jellyfish® cartridges and record necessary information water pressure may damage the tentacles that will establish whether a major service is required. a. Position tentacle in a container (to capture Establish a safe working area around the runoff) with the open end facing down access point b. Rinse entire length of cartridge using only low pressure water source (€.g. garden hose) Remove access covers . c. Evaluate and note the condition of the tentacles oo Using a vacuum unit or net remove any floatable d. Ensure runoff is disposed appropriately gross pollutants contained behind the maintenance , ; ; e. Re-assemble cartridges ready for reinstallation* access wall o Using a vacuum unit decant the water until the level a Wash down deck level to remove any built up drops below the base of the cartridges Sediment (if required) a Measure the level of accumulated sediment in the chamber if depth is greater than 300mm use vacuum unit to remove sediment o Remove Jellyfish® cartridges* a. Remove cartridge lid b. Remove cartridges vertically from chamber, i ish® i lifting from eye nut lifting points only Re-install Jellyfish” cartridges c. Replace and secure cartridge lid back into deck a. Remove cartridge lid to reduce trip hazards during maintenance b. Lower cartridge into chamber, lifting from eye nut lifting points only GB Unscrew all 11 tentacles from the cartridge head plate, keep all components for reassembly* c. Insert cartridge vertically into cartridge receptacle, and secure cartridge lid back in place Replace access covers “Refer Appendix 1 for Jellyfish® Cartridge Schematic 6 Ocean Protect Jellyfish” Filter 9?
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Judgment - Stockwell v Noosa Council - PEC Appeal 1998 of 2024 - 26.06.25.pdfRelated documentApplication case desk ↗
About this file
- File size
- 21.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.