Lanscaping Specification URB-P0003847-000-SP-240719

of 60

Page text shows just the words. Original shows the document exactly as it was published.

 Slip rating – Wet Pendulum Class rating ‘P4’ and slip resistant R11. All areas steeper than 1:14 to be Wet
 Pendulum Class rating ‘P5’ and slip resistant R12D.
 Sealer – Penetration, non-yellowing protective sealer for concrete floors. CCS Streetscape or approved
 equivalent.
 Sub-base depth / material – As per structural engineer’s documentation. Remove any soft areas that could
 lead to settlement and cracking and replace with suitable compacted material capable of supporting the base
 material
 Reinforcing – F72 mesh, min. 50 mm top cover as per structural engineer’s documentation
 Expansion joints - 10mm thick bitumen impregnated fibreboard. Locate expansion joints at 5m intervals unless
 shown otherwise on the drawings
 Control joints - Tooled control joints at 3m intervals unless shown otherwise on the drawings




 PA06: Pavement Profile – Concrete – Vehicular for Pickle Ball Court

 Pickle Ball Court
 Dimensions: Length – 13,41m long, 6,10m wide
 Material – In-situ concrete. 175mm thickness. Normal class. Minimum grade N32.
 Colour – Grey cement
 Aggregates – no
 Supplier –– Boral or approved equivalent.
 Surface Finish – broom finish
 Slip rating – Wet Pendulum Class rating ‘P4’ and slip resistant R11. All areas steeper than 1:14 to be Wet
 Pendulum Class rating ‘P5’ and slip resistant R12.
 Base depth / material - 125mm thick as per structural engineers’ documentation
 Sub-base depth / material – As per structural engineer’s documentation. Remove any soft areas that could
 lead to settlement and cracking and replace with suitable compacted material capable of supporting the base
 material
 Reinforcing – F72 mesh, min. 50 mm top cover as per structural engineer’s documentation
 Expansion joints - 10mm thick bitumen impregnated fibreboard. Locate expansion joints at 5m intervals unless
 shown otherwise on the drawings
 Control joints - Tooled control joints at 2m intervals unless shown otherwise on the drawings.

 Surface Colour:
 Colour – Full surface colour application
 Installation- Installed to manufactures specification (StreetBond150™), and Australian standards.
 Provide installation certificate specifying product type and specification.




URBIS
URB-P0003847-000-SP.DOCX                                                                              PAGE   17
Log in to download the original file

Lanscaping Specification URB-P0003847-000-SP-240719.pdf · 1.5 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.