               GENERAL COMMITTEE MEETING REPORT                                                           17 MARCH 2025




                Figure 13 – Building height comparison from natural ground (red line - left) and from FFL 2.7 AHD (red line –
                                                      right) Gympie Terrace section

               The Applicant’s response to this matter has involved numerous design amendments including
               reducing the number of roof top terraces from 6 to 2 and use of sympathetic building materials
               involving recycled timber for construction of the roof top terrace pergolas.
               Figure 12 indicates two red line measurements of 12 metres building height measured from ground
               level and from the flood level of 2.7 AHD. Importantly, the three storeys will be contained within a
               maximum 12 metre height when measured from ground level or flood level (Figure 13 - red lines).
               It is acknowledged that as part of the applicant’s response to Councils Information request
               substantial amendments were made to the roof volume by reducing the number of roof top terraces
               (from 6 to 2) and removal of communal facilities which reduced the bulk of the roof and maximum
               height from RL 16.9 to 15.6.
               PO9 of the code requires that building height is consistent with structures on adjoining and
               surrounding premises and do not visually dominate the street or surrounding area. Existing
               development to the east, south and west of the site contain buildings which are three storeys in
               height.
               The building is setback 9.3 metres from the southern side boundary which will ensure
               overshadowing does not occur to the adjoining residential resort property (Twin Quays/ 9 Albert
               Street).
               It is agreed that due to site flooding an allowance should be made to consider building height above
               12 metres from ground level. Building floor-to-ceiling heights are an appropriate height with


                                                                                                              Page 41 of 55



Document Set ID: 23659553
                   23546364
Version: 1,
         20,Version
             VersionDate:
                     Date:27/03/2025
                           12/03/2025
Log in to download the original file

ATTACHMENT 3 - (MCU24_0074) - PLANNER'S REPORT 17 MARCH 2025.pdf · 13.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.