Log in to see the plans as drawnSteps For Cartridge Replacement Maintenance
1 Depending on the particular unit, one or two utility 14 Using the appropriate lifting cap, attach the cable and
workers and a hauling truck operator will deliver remove the cartridge (up to 10kgs. each) from the
the replacement cartridges to the site. Information vault. It is strictly prohibited to have personnel standing
concerning how to obtain the replacement cartridges is under suspended cartridges. Care must also be used
available from Stormwater360. to avoid damaging the cartridges during removal
and installation. The cost of repairing components
2 If applicable, set up safety equipment to protect
damaged during maintenance will be the responsibility
pedestrians from fall hazards presented by open
of the owner unless Stormwater360 is performing
doors. Also, set up appropriate safety equipment for
maintenance activities and damage is not related to
work near roadways.
discharges to the system.
3 Inspect the external condition of the unit and take
15 Set the used cartridge aside or load onto the
notes concerning defects/problems.
hauling truck.
4 Open the doors to the vault and allow the system to air
16 Repeat steps 14 to 15 until all cartridges have
out for 5-10 minutes.
been removed.
5 Without entering the vault, give the inside of the unit,
17 Remove deposited sediment from the floor of the vault.
including components, a general condition inspection.
This can be accomplished by using the vacuum truck
6 Make notes about the external and internal condition.
18 Once the sediments are removed, it is necessary
7 Give particular attention to recording the level of to assess the condition of the vault, particularly
sediment build-up on the floor of the vault and on top the manifold and the connectors. These are short
of the internal components. sections of 2-inch schedule 50 PVC, or threaded
Ensuring safe working procedures are met, off load the schedule 80 PVC that should protrude above the floor
8
replacement cartridges (16-39kgs each) and set aside. of the vault. If required, apply a light coating of FDA
approved silicon grease to the outside of the exposed
9 Remove the top cap (threaded), upper seal and portion of the connectors. This ensures a watertight
float from the cartridge. Repeat procedure for every connection between the cartridge and the drainage
cartridge within StormFilter vault. Place items in a large pipe. Replace any damaged connectors.
plastic container to be lifted form the vault.
19 Using the boom, crane, or tripod, lower and install
10 Using a cordless drill and 8mm hex head, remove the new cartridges (typically 30kg for standard
the three screws located around the top perimeter of 460 cartridges). Once again, take care not to
the cartridge hood. Place screws in the large plastic damage connectors.
container and, once full or completed, remove plastic
container from vault. 20 Close and fasten the access cover, and remove
safety equipment.
11 Move the vacuum truck near the StormFilter vault
on the down-wind side. Be sure that the truck is not 21 Make notes about the local drainage area relative
too close to the vault so that fumes will not enter the to ongoing construction, erosion problems, or high
vault. Make sure that the last 500mm of the nozzle is loadings of other materials to the system.
approximately 100-125mm in outside diameter. 22 Finally, dispose of the residual materials in accordance
Feed vacuum nozzle into cartridge bay and start with applicable regulations. Make arrangements to
12
vacuum truck. Remove cartridge hood and place return the used cartridges to Stormwater360.
nozzle directly onto filter media. Completely remove
media from each cartridge and repeat process for
every cartridge in vault.
13 Once completed disconnect cartridges from vault floor
and place hood back on cartridges