Your Mates Bowlsy Pty Ltd                                                                       Reference: #1859d1-B
Your Mates Bowls Pub                                                                              Date: 6 March 2025
Noise Impact Assessment

It is recommended that a detailed assessment of mechanical plant noise be conducted in
accordance with the criteria and assessment procedure outlined in Liquor guideline 51: Preparing
an acoustic report. This would allow for determination of noise limits associated with the
cumulative noise emissions of amplified entertainment, patron noise and mechanical plant noise.
Further discussion is provided in Section 5.2.

Any future mechanical plant should be selected to ensure compliance with the established noise
criteria in Section 3 of this report.

4.7 Noise Sources
Table 9 below describes the noise source model inputs associated with each activity and includes
the overall sound power levels utilised in the prediction model.

                                       Table 9. Noise Source Properties
                                                                   Source
                                                                    Height          Noise
                                 Noise       Lw,
           Activity                                  Lp, dBA     (above local      Source          Reference
                               descriptor    dBA
                                                                   ground /         Type
                                                                   surface)

                                                   Mechanical plant

  Roof-mounted kitchen                                                                          Measured noise
                              LAeq,adj,1hr   92         --          1.0 m         Continuous
       exhaust fan                                                                             level (Section 4.6)

    Patton refrigeration                                                                        Measured noise
                              LAeq,adj,1hr   76         --          2.0 m         Continuous
           plant                                                                               level (Section 4.6)

                                                   Carpark activities

   Commercial delivery
                                                                                               LIA Measurement
   vehicle movements          LAeq,adj,1hr   97         --          1.5 m          Variable
                                                                                                   Database
      (base value)

    Commercial delivery
  truck at idle with truck-                                                                    LIA Measurement
                              LAeq,adj,1hr   85         --          2.3 m          Variable
   mounted refrigeration                                                                           Database
         operating

                                       Amplified entertainment and patron noise

  Male talker at a ‘raised
                                                                                                AAAC Licensed
    voice’ vocal effort                               66 at
                              LAeq,adj,1hr    --                    1.5 m          Variable    Premises Guideline
     (Cushing et al) –                                 1m
                                                                                                     V3.0
   reference spectra [1]

     Interior Dining &
                                                                                               LIA Measurement
   Functions amplified
                                                       102                                     Database and LIA
      entertainment           LAeq,adj,1hr    --                         --        Variable
                                                     (Lp,rev)                                    Guideline 51
 (calculated reverberant
                                                                                                  Assessment
            SPL)

     Outdoor portable                                                                          LIA Measurement
                              LAeq,adj,1hr   88         --          2.0 m          Variable
        speakers                                                                                   Database

                                                   Playground use

      Children playing        LAeq,adj,1hr   87         --              0.9m       Variable    AAAC Guideline for



Live It Acoustics                                                                                            Page 14
Log in to download the original file

Appendix B - Acoustic Report.pdf · 4.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.