2022021498S0_30-32 James Street_SoAS_Approval · MCU21/0027.02

of 3

Text shows just the words. Original shows the document exactly as it was published.

                                  A&C - Statement of Alternative Solutions
                                                                                       Accreditation and Certification

ABN: 89 791 717 472




 Purpose:
 In accordance with section 3.3.16 of the Unitywater Accreditation and Certification Manual, any deviation from
 the Unitywater Connections Policy, the SEQ Code or the Unitywater Accreditation and Certification Manual (A&C
 Manual) will need to be documented and alternative solutions must be proposed by a Major Connections
 Certifier.
 A Statement of Alternative Solutions ‘SoAS’ for any deviation from standards must be sufficiently detailed to
 ensure the Unitywater Auditor is able to fully understand the ‘deviation’ and the proposed ‘alternative solution’.
 Further, the SoAS Communicates the ‘justification’ for an alternative solution to the deviation from the relevant
 standard to successfully meet requirements of the Prudency and Efficiency test (See Appendix F of the
 Unitywater Accreditation and Certification Manual).
 Non-conforming Alternative Solutions to SEQ Code standards must be proposed by a Major Connection Certifier
 only.



                                                Application Details

 SoAS Date:                                         18/09/2023
 Registered Certifier:                              Brad Downes ACR/MAJ 2018-008
 Certifier Category:                                Major Connections Certifier
 Street Address:                                    30 James Street, Noosaville
 Estate Name: (Where Applicable)                    N/A
 Stage Number: (Where Applicable)                   N/A
 Item 1: Proposed Non-conforming Acceptable Solution
 What is the proposed non-conforming item?
 Clearance between existing 100mm diameter water main and proposed stormwater pipe.
 Where is the non-conforming item located?
 Frontage of the development site.
 Which standard is the non-conforming item attributed to?
 Water Supply Code V1.3-2019, section 5.12.5.2 Clearance Requirements
 Why can’t the relevant Connections Policy, SEQ Code standard(s), or A&C Manual requirement
 be achieved?
 The construction works require an amendment to the stormwater design requiring stormwater to cross
 at different location (approximately 8m north) than that originally nominated on the design drawings.
 The clearance from the existing water main to the newly proposed stormwater pipe will not meet the
 requirements of the SEQ Code. It is worthwhile noting there is currently a stormwater pipe in the same
 location that also doesn’t meet the requirements of the SEQ Code.

 Reasons for accepting a non-standard solution:

      •    The requirement to shut off a large section of the existing water main servicing existing
           dwellings to achieve an additional 100mm separation from the proposed stormwater pipe
           crossing. This area is relatively high density and therefore likely to impact a number of users.



                                                                                                                  Page 1 of 2
Document No: F10719            Revision No: 4               Last Review Date: 21/09/2022           Next Review Date: 21/09/2024
Full text of the other 2 pages

Page 2

      •    The existing pipe is reinforced concrete (RCP) and the newly proposed pipe is polypropylene
           (PP) which is lighter and therefore ultimately resulting in reduced loading of the existing water
           main.
      •    The proposed solution provides additional clearance to the existing water main from what is
           currently provided.
      •    The water table is quite high in this area and therefore the construction associated with lowering
           the main will pose difficulties. There are also a number of services within the existing verge
           profile adding to the difficulties associated with lowering the existing water main.
 What is the Alternative Solution proposed for the non-conforming item?
 Leave the existing water main in its current location.
 How does the Alternative Solution satisfy the Prudency and Efficiency test?
 This solution satisfies the prudency and efficiency test as relocating the water main will likely result in
 the shutoff of water to a relatively large number of dwellings. The proposal is an improvement from
 the current situation.
 Registered Certifier supporting comments: As the area is sand based, construction of the
 stormwater pipe will involve hydro-compaction (water jetting) to ensure mechanical vibration above the
 existing water main is not undertaken.
 List of supporting Attachments (where applicable):
 Drawing 31026C1.1 Revision D




                                                                                                        Page 2 of 2
Document No: F10719            Revision No: 4           Last Review Date: 21/09/2022     Next Review Date: 21/09/2024

Page 3

                                                                                                                                                                                             SP156216
                                                                                                                                                       3                                     6
                                                                    4                                                                             RP78252
                                                                  RP78252
                                                                                                        89°59'15"
                                                                                                         71.545
                                    WM                                                                                                                                                           6
                                                                                                                                                                                     GTP671
                                H                                                                                                        Pool    4          Office Building
    STREET




                                                                                        Single Storey                                           985m²
                                                                                        Unit Building


                                                                                                                                         Deck                                       GTP671




                                                                                                                                                                                179°59'15"
                                                                                                                                                                              27.534
             BM: Nail in Kerb
    JAMES




             RL: 1.34



                                                                                                                            3                                                          Emt A
                                                                                                                                                                                      RP142979


                                                                                                                           985m²
                                    359°59'15"
                                     27.534




                                                                        Single Storey
                                                                        Unit Building
                                                                                                                Building                         Carports



                                     WM




                                                                                                                     71.545




                                                                                                                                                                                                        SP174678
                                                                                                                    269°59'15"

                                                                                                                                                                      4
                                                                                                                                                              GTP103989
                                                         1                                     2                                   3
                                                      GTP103989                         GTP103989                            GTP103989
                                                 CP
                                         GTP103989


                                                                                                                                                                                                                                Issue:

B




                                                                                                                                                                                                                                                         Unit 1/11 Project Ave,
                                                                                                                                                                                                                                                         Noosa Heads
                                                                                                                                                                                                                                                         Ph (07) 5455 5604




                                                                                                                                                                                                                                DEBUILD T/A
                                                                                                                                                                                                                                                         email:[email protected]
                                                                                                                                                                                                                                                         web:www.scg-engineers.com
                                                                                                                                                                                                                                                         ABN 40 098 481 899

                                                                                                                                                                                                                   1.73
                                                                                                                                                                                                                       1.
                                                                                                                                                                                                                                    Title:




                                                                                                                                                                                                                                   Project




                                                                                                                                                                                                                                   Date:       Drawn                Design
                                                                                                                                                                                       C
                                                                                                                                                                                                                                    Checked:   Drg No.                        Rev.




                                                                                                                                                                                                                            R

Used in these records

About this file

File size
891 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2022021498S0_30-32 James Street_SoAS_Approval.pdf · 891 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.