Original source · versioned page text
Bushfire Hazard Assessment
BHA Report for36 Riverpark Drive, Ringtail Creek
Performance Outcomes Acceptable Outcomes Compliance
PO5 AO5
Public safety and the environment are Hazardous materials are not Not Applicable
not adversely affected by the impacts of manufactured or stored in bulk in a
bushfire on hazardous materials bushfire hazard area.
manufacturing or storing in bulk.
PO6 AO6.1 The access road will have:
Roads provide for easy and safe The road layout provides for through- 1. a cleared minimum width of 6
evacuation of residents of premises roads and avoids cul-de-sacs and dead- metres;
and access by emergency services. end roads. 2. a maximum gradient of 12.5%;
OR 3. provide unbroken access for
AO6.2 fire fighting vehicles;
The development has a perimeter road 4. provide passing bays and
reserve with a minimum width of 20 turning areas;
metres and maximum gradient of
12.5%.
OR
AO6.3 The nature of the development prevents
Cul-de-sacs or no-through roads are the provision of alternative access. A
provided with fire trails safe refuge area exists to the north of
or access easements, which are capable the the proposed development.
of being navigated by conventional
vehicles and which link to through
roads.
AO6.4
Safe access and egress is available at
all times to all of the development for
emergency vehicles and personnel.
AO6.5
Where an emergency access point is
required, it complies with the
relevant works codes and PSP6
Engineering Design Standards.
+ Bushfire assessments
+ Property vegetation assessments
+ Site planning for bushfire
+ Property management for bushfire Bushfire Planning Specalists - qldbushfireplanning.com.au
+ Bushfire management plans
See the original
The page text is free to read. Viewing or downloading an original file needs an account.