Performance Outcomes Acceptable Outcomes Response
requirements for wastewater
management.
PO16 A016
On-site effluent treatment and An onsite effluent system and
disposal systems are designed, disposal area is:
constructed and managed to not
a) not located on a slope
compromise the environmental
greater than 1 in (10%);
values of waters and water
b) not located at or below
quality objectives.
the 1% annual
exceedance probability
(AEP flood event);
c) not located within a
riparian buffer area
mapped on a
Biodiversity, Waterways
and Wetlands Overlay
Map; and
d) setback 400 metres
minimum from the full
supply level of Lake
Macdonald.
Editor’s Note—The Plumbing and
Drainage Act 2003 sets out
requirements for on-site effluent
treatment and disposal. The Queensland
Plumbing and Wastewater Code and
associated guidelines are used to
confirm the suitability of each site to
accommodate an on-site sewerage
facility; or where a centrally located
group collection treatment system is
proposed, confirmation as to the
suitability of the designated site to
accommodate the on-site sewerage
facility. Additionally, where the
combined total peak design capacity of
effluent treatment is less than 21
equivalent persons, the design of the
system achieves a low to medium risk
classification in accordance with
Seqwater’s Land Use Risk Tool for
onsite sewerage facilities.