07/0387 - Submitted plans [As Published] · 142007.387
Plans and drawings: the text below has words only, no drawings.
a
Revision | Description Date
Refer
DISCHARGE PIPE SIZE 16115-H4 for A. Re issued plans. 11.10.06.
suoply. Dashed drainage at 8. Hydraulic revised. 16.04.07.
Fixture [ON upp
[ oer
e io trays, 50 co
SHR 40 waste to FP. “o
we 100
SK 50
tT 65
FWG 65
Mott 9/06/2006 4:34 PM 1611S-H1-H4.dwg
Reter
16115-H4 for
a ;
connection.
General Notes :
1. Hydraulic services shown are diagramatic only. Refer to architectural
drawings for locations of fixtures.
2 All Sonitary Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3500.
3. All work shall comply with the requirements of cuthorities having
jurisdiction, after obtaining all necessary permits and approvals.
4. The contractor is to confirm the position of all existing services as
indicated on these and associated plans prior to the commencing of
work,
5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
(U.N.0.) pipe. Over 2254 Concrete Rubber Ring Joint (RRW) Class 3. All
pipes U.N.0. to be laid at @ minimum grade of 1 in 100 U.N.O, Joins ore
to be constructed in accordance with the manufacturers requirements.
6. Sewers 100mm diam. uPVC DWV (U.N.O.) and laid at o minimum
grede of 1 in 60.
7. Water supply pipework below ground is to be ;
63mm diam. or less = High Density Type 50
Cass 12 Polyethylene
8. All above ground and internal water supply pipework to be Type B
Copper.
pe 9, Woter services are not permitted in ground slabs and all joins and
? connections shall be made above the slab.
|
|
|
|
10. Fire Hydrants are to be installed are to be installed in accordance
with AS2419.1, Hose Reels ore to be installed in accordance with AS2441.
11. Clean-outs, Inspection openings and Closing caps situcted in
vehicular or pedestrion pavements are to be fitted with either brass or
cast-iron covers,
40 12, All in-ground valves shall be in accordance in approved concrete
{ doshed drainage at path boxes.
Refer : - higher level. 13. All waste pipes and water services penetrating slabs to be wrapped
16115-H4 for HWu's on safe \ in an approved flexible joint joint wrapping.
supply. — trays, 50 . 14. The term SERVICE’ refers to the m
waste to FP. unless noted otherwise.
um internal pipe diameter
BASEMENT FLOOR PLAN DESO TR
Se CONSULTING ENGINEERS x)
©] sirwetaral - civil - geelectinical SS
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND _ KEY Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
Ca
; UPVC Sewer, size grade and invert =a Stormwater pipe, size, grade and invert 5 .
8 Bath HCB House Connection Branch NRV Non-Retum Valve TG Test Gate level as noted levels as noted Title: internal Hydraulics Arrangement
COQ Clean—Out HR 36m Fire Hose Reet ORG Overflow Relief Gully V Vent —W— External Poly Water Service, size as noted ‘y he Cold and Hot Water riser -
DP Rainwater Down~Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Ba riser locations and size. Project Lot 161 Orealla Cres
FP Frog Flap IC Inspection Chamber SC Stop Cock VC Vent Cowl —w— Sanitary Stack number and Vent size Sunrise Beach
{internal Cold Water service &—
FWG Floor Waste Guily 10 Inspection Opening SHR Shower WC Water Closet
HC Hose Cock Loundry Tub SK Sink WM = Washing Machine | —HW—
30.01.05
Rev.
Interna! Hot Water service —@) = Fixture Unit loading, ‘| Date: May 2006 Drg No. 16115-H3 B
Few,
2410472007 4:56:44 PM, 1:1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Submitted plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.