07/0387 - Submitted plans [As Published] · 142007.387
Plans and drawings: the text below has words only, no drawings.
Revision | Description Date
DISCHARGE PIPE SIZE A. Re issued plans. 11.10.06.
FIXTURE ON B. Stack detail marks added. 16.04.07.
vB 40
B 40
SHR 40
WC 100
5K 50 |
UT 65 ti
FWG 65 fe
Z wott 9/06/2006 4:34 PM 18115—-Hi-H4.dwg
------4y---- A Dropper to lower level refer
7 drawing H3 for location.
7
|
|
|
TTS
7
IN
General Notes :
1. Hydraulic services shown ore diagramatic only. Refer to architectural
drawings for locations of fixtures.
FWG I 2 All Sonitory Hydraulics and Water Reticulation within the allotment
| boundary to be in accordance with AS3500.
3. All work shall comply with the requirements of authorities having
Wg WC prisdiction, after obtaining all necessary permits and approvals.
4. The contractor is to confirm the position of all existing services as
VBS we indicated on these and associated plans prior to the commencing of
work.
5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
{U.N.O.) pipe. Over 2259 Concrete Rubber Ring Joint (RRU) Class 3. All
es U.N.O. to be laid at a minimum grade of 1 in 100 U.N.O. Joins ore
to be constructed in accordance with the manufacturers requirements.
| 6. Sewers 100mm diom. uPVC DWV (U.N.0.} ond laid at a minimum
| grade of i in 60.
| 7. Water supply pipework below ground is to be ;
| 63mm diam. or less - High Density Type 50
| Goss 12 Polyethylene
8. All above ground and intemal woter supply pipework to be Type B
i
!
I
|
Kk
SSL
I
@)
@)
Copper.
9. Water services are not permitted in ground slabs and all joins and
connections shall be made above the slab.
10, Fire Hydrants are to be installed are to be installed in accordance
Dropper to lower level refetyith AS24194. Hose Reels are to be installed in accordance with AS244I.
drawing H3 for location.
Oo}
11. Glean-outs, Inspection openings and Closing caps situated in
vehicular or pedestrian pavements are to be fitted with either brass or
C0 cast-iron covers.
12. All in-ground volves shall be in accordance in approved concrete
path boxes.
13. All waste pipes and water services penetrating slabs to be wrapped
in an approved flexible joint joint wrapping.
14. The term ‘SERVICE’ refers to the minimum internal pipe diameter
GROUND FLOOR PLAN unless noted otherwise.
Z
|
I
I
\
|
|
L
!
|
|
|
|
I
el __-_-«
DESULD TA
CONSULTING
SC structural = Gi
ABN 40 098 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
UPVC Sewer, size grade ond invert cmcmcmc = - Stormwater pipe, size, grade and invert . .
B Bath HCB House Connection Branch NRV Non-Return Valve TG Test Gate level as noted levels as noted Title: Internal Hydraulics Arrangement
CO Clean-Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V Vent —wW— - Extemol Poly Water Service, size as noted Sy ‘fe Cold and Hot Weter riser -
DP Rainwater Down-Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin riser locations and size. Project Lot 161 Oreaila Cres
FP Frog Flap (C Inspection Chamber SC Stop Cock VC Vent Cowl —CW— ~— Intemal Cold Water service &— Sanitary Stack number and Vent size Sunrise Beach
HC Hose Cock Laundry Tub SK Sink WM = Washing Machine | —HW—
FWG Floor Waste Gully 10 Inspection Opening SHR Shower “WC Woter Closet
Internat Hot Water service —®) ~ Fixture Unit foading. Date: May 2006 Drg No. 16115-H2 B
Fev, - 30.01.05
24/08!2007 4:86:17 PM, 1:1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Submitted plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.