Original source · versioned page text
Assessment Report 16 Grant Street Noosa 071217
Attached to the e-mail Multiple Housing Type 2 Duplex - MCU17/0559.
Specific Outcomes Probable Solutions Proposed Solutions
DIFFERENT SHADOW LINES AND IS building materials; and
VISUALLY INTERESTING e) visually break up the bulk of the e) the bulk of the building is
building by integrating tall plant further broken up by the use of the
species in front of and to the side of colonnaded arbour to each side of
buildings; the building which softens the
AND edges to those facades
S38.3
For corner sites the building design S38.3 Not Applicable
addresses both street frontages The site is not a corner site.
by— a) including doors and
windows on each face of the
building that fronts a road; and
b) incorporating an access point
from each street, one for each of
the dwelling units.
Garages and carports
O39 S39.1 SO39.1 Complies
Garages, carport structures and Garages and carports have a front The proposed garages are
vehicle manoeuvring areas are boundary setback of at least 6m setback 7metres to Grant Street.
designed and sited to— provided that garages may be
a) provide for resident and visitor setback 5.5m from the front
parking; boundary where garage doors are
b) visually integrate with the building staggered 1m from each other in
and to not dominate the street front; relation to the frontage
c) allow opportunity for landscaping to AND SO39.2 Performance Solution
screen vehicle parking and S39.2 Each dwelling unit has a garage
manoeuvring areas; Garages present a minimum width with a width of 5.8metres however
d) minimise the number of driveway to the streetscape (the total width of this represents more than 50% of
accesses; and garage doors is no more than 6m or the frontage for each lot. The
e) allow safe and efficient access to 50% of the frontage width, proposal has been designed such
and egress from the premises. whichever is the lesser, where the that the fence to Grant Street is
structure faces the street) narrowed t reduce the appearance
AND of the access and garage. In
addition the dwelling is set forward
of the garage doors to avoid the
garage visually dominating the
view of the building from the
street.
S39.3
Where multiple double garages are SO39.3 Complies
included garages are stepped back The proposed garages are
a minimum of 600mm from each setback 1 metre from the front of
other, in relation to the frontage or the building at the upper level.
are separated by at least 2m;
OR
S39.4 SO39.4 Not Applicable
Garages that are visible from, but The proposed garages face Grant
do not face the street, include Street.
windows or other articulation and
have a 6m vegetated buffer
PI Home Pty Ltd 27
16 Grant Street, Noosa
See the original
The page text is free to read. Viewing or downloading an original file needs an account.