Original source · versioned page text
Assessment Report 16 Grant Street Noosa 071217
Attached to the e-mail Multiple Housing Type 2 Duplex - MCU17/0559.
SO4 PS4.1 & PS5.1 PS4.1 & PS5.1 Not Applicable
15
On-site water storage is designed For a Class 1 building other than a The subject site is not located
and operated to support the efficient Detached house or Multiple outside a reticulated water service
use of water; Housing Type 1, outside a area.
reticulated water service area, a
AND rainwater tank is to be installed with
the following minimum storage
SO5 capacities—
On-site water storage is adequate a) Where no more than 3
for occupants every day use and fire bedrooms – 45,000 litres; or
fighting purposes. b) Where more than 3 bedrooms
– 60,000 litres;
AND
c) There is to be on the lot a dam,
swimming pool or water tank
accessible for use by the fire
brigade that contains at least
5,000 litres of water.
Advisory note
The 5,000 litres required can be
included within the water required in
S4.2 or S5.1 providing it is
accessible for the purpose of fire
fighting at all times and not used for
other domestic purposes.
Erosion and Sediment Control
SO6 PS6 SO6 Complies
Development does not cause No solution provided The proposal is for a Multiple
erosion or result in transport of Dwelling Type 2 duplex and will not
sediments off-site.
Advisory Note cause erosion or result in transport
Persons undertaking development, including of sediments off-site. All works will
building work, are required under the
Environmental Protection (Water) Policy 1997
be undertaken in accordance with
(EPP) to ensure that sediment and other Council requirements.
material including building waste, sawdust,
concrete, cement or paint are not deposited or
released into a roadside gutter, stormwater
drain or waterway, or into a place where it
could reasonably be expected to move or be
washed into a roadside gutter, stormwater
drain or waterway and are not washed from
the site. Council enforces the EPP and
penalties may apply.
Safety and Security
SO7 PS7.1 PS7.1 Complies
For Multiple Housing Types 2, 3 The building entrance is clearly The entrances to both dwelling units
and 4, buildings and outdoor spaces identifiable and visible from the will be clearly visible from Grant
are designed to protect the personal street, footpath and driveway;
Street.
security and safety of residents by AND
allowing for natural surveillance.
PS7.2 PS7.2 Complies
The internal path network has clear The proposal will include internal
sightlines to the dwelling entry and paths with a clear sightline to the
street access points; dwelling entrances and street
AND access points.