Original source · versioned page text
Assessment Report 16 Grant Street Noosa 071217
Attached to the e-mail Multiple Housing Type 2 Duplex - MCU17/0559.
PS7.3 PS7.3 Complies
Visitors have direct access to the The proposal will include entries
entrance without passing through which do not require passing
private outdoor living areas. through outdoor living areas.
Emergency Access
SO8 PS08 SO8 Not Applicable
For Multiple housing Type 3, 4 & No solution provided. The proposal is for a Multiple
5, site design and layout ensures Dwelling Type 2 duplex.
efficient access and egress for
emergency vehicles.
Basement Drainage
SO9 PS9.1 PS9.1 Complies
Buildings and access works are Enclosed car parking and The proposal includes car parking
designed and sited to protect manoeuvring areas are constructed and manoeuvring area which allows
persons and property in the event of at a level that permits the parking
for drainage from the site by gravity.
a flood and power failure. area to drain from the site by gravity
means, without the need for
mechanical pumping.
Separation of Incompatible Uses
SO10 PS10.1 PS10.1 Complies
Development is designed to Bedroom windows are at least 3m Bedroom windows will be at least
minimise noise carrying between away from shared driveways or 3m away from shared driveways or
dwelling units or accommodation carparking areas of adjacent
carparking areas of adjacent
units by locating noise sensitive dwelling units or accommodation
spaces such as bedrooms away units. dwelling units or accommodation
from noise generating areas of the units.
development, such as carparking
areas or mechanic plant and
equipment or recreational facilities.
Mechanical Plant and Equipment
SO11 PS11.1 PS11.1 Complies
Mechanical plant and equipment Mechanical plant and equipment, Mechanical plant and equipment
associated with Residential Uses including pool and spa pumps, pool will be located in accordance with
are designed and located so as not heaters, air-conditioning units and
Council requirements.
have an adverse impact on the refrigeration units are—
visual amenity of the site or a) where located at ground level,
surrounding areas. screened by fencing 1.5m in
height or dense vegetation of at
least 1.5m in width
incorporating grouped trees
and shrubs with maximum
separation distance of 1m
measured from the centre of
the plant; and
b) for Multiple housing Type 2, 3
& 4 are visually integrated into
the line and plane of the
building and roof design and do
not project beyond the height or
width of the building when
viewed from the street and
adjoining properties.
Ancillary Recreation Uses
PI Home Pty Ltd 31
16 Grant Street, Noosa
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original