Assessment Report 16 Grant Street Noosa 071217

Attached to the e-mail Multiple Housing Type 2 Duplex - MCU17/0559.

of 50

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

           Existing Services Code:

Specific Outcomes                     Probable Solutions                       Proposed Solutions

Setbacks and easements
O1                                    S1.1                                     S1.1 & PS7.1 Performance
Development near a sewer, water       The footing of any structure or          Solution
main, stormwater drain, overland      building is located clear of the zone    The Detailed Infrastructure Map
flow path or associated structure     of influence but no closer than 1.5m     provided at Attachment C shows
does not—                             (measured horizontally) from             that there is an existing sewer
a) adversely affect the function of   infrastructure including sewers, water   gravity main running along the
the service;                          mains and stormwater structures;         northern boundary of the site.
b) place an additional load on the    AND
service; and                                                                   The proposal has been sited and
c) unduly increase future             S1.2                                     designed to avoid this main with
maintenance costs.                    No building or structure overhangs       only the arbour and stairs sitting
                                      the zone of influence;                   above the main. It is considered
                                       AND                                     that these structures will not have
                                                                               any adverse affect on the function of
                                      S1.3                                     this main or increase maintenance
                                      Finished surface levels maintain a       costs. All works in proximity to his
                                      minimum of 600mm of cover, but no        main will be in accordance with
                                      greater than 3m of cover to the          Council standards.
                                      underground infrastructure;
                                      AND

                                      S1.4 If the existing surface level is
                                      altered, surface level services
                                      including manholes and inspection
                                      points are altered to match the new
                                      surface level;
                                      AND

                                      S1.5 Alterations are constructed in
                                      accordance with Section 4 of PSP5 –
                                      Engineering Design Standards –
                                      Roads, Drainage and Earthworks
                                      and applicable water and sewerage
                                      design standards;
                                      OR

                                      S1.6 Existing services are relocated
                                      and the design and construction of
                                      the relocated services is in
                                      accordance with Section 4 of PSP5 –
                                      Engineering Design Standards –
                                      Roads, Drainage and Earthworks
                                      and applicable water and sewerage
                                      design standards




PI Home Pty Ltd                                                                                            42
16 Grant Street, Noosa
Log in to download the original file

Assessment Report 16 Grant Street Noosa 071217.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.