Assessment Report 16 Grant Street Noosa 071217

Attached to the e-mail Multiple Housing Type 2 Duplex - MCU17/0559.

of 50

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

O2                                   S2.1                                     PS2.1 - S2.3 Complies
Maintenance access is provided to    For trunk infrastructure a registered    The proposal will ensure access to
all sewers, water mains,             easement in favour of Council is         all services over the site in
                                     created over all underground
stormwater drains, overland flow                                              accordance with council standards.
                                     infrastructure located in private
paths and associated structures.     property;
                                      AND

                                     S2.2
                                     The width of the easement is the
                                     greater of 3m or the width of the zone
                                     of influence;
                                     AND

                                     S2.3
                                      The easement is centred over the
                                     centreline of the infrastructure

             Transport Roads and Drainage Code:

The development of new road does not form part of the proposal at hand and as such the Transport
Roads and Drainage Code will not be responded to.


             Waste Management Code:

The proposal at hand is for a Multiple Housing Type 2 Duplex and will utilise the existing adequate areas
for the collection and separate storage of waste material. As such the Waste Management Code will not
be addressed.

             Water Sensitive Design Code:

Specific Outcomes                    Probable Solutions                       Proposed Solutions

Water Reuse
SO1-SO5 Not Applicable
Water reuse does not form part of the proposal at hand.
Run-Off Treatment
SO6                                  PS6.1 & PS7.1                            PS6.1 & PS7.1 Complies
Run-off that leaves the site is      Development complies with the water      The proposal at hand will comply
treated so as not to adversely       quality standards in Table 2 of the      with the water quality standards in
impact on the ecology and            SEQ Regional Plan Implementation         the relevant provisions of the SEQ
hydrology of downstream              Guideline No. 7 for Water Sensitive      Regional Plan.
environmental flows;                 Urban Design.

AND

SO7
Within the Shire Business Centre
site, as shown on Map SBC—
a) run-off treatment occurs within
the site ; and


PI Home Pty Ltd                                                                                           43
16 Grant Street, Noosa
Log in to download the original file

Assessment Report 16 Grant Street Noosa 071217.pdf · 1.3 MB (small file)