(b) windows and other openings are permanently screened
to a minimum height of 1.7 metres to avoid overlooking;
(c) windows and doors use translucent glazing to obscure
views; or
(d) windows or balconies are offset by 45 degrees or more.
Editor's note—refer to figure AP31A and figure AP31C
AO17AO19.4
Planter boxes, screens, pergolas, landscaping and architectural
design of balconies are used to screen the ground floor private
open space of dwellings from separate upper level dwellings.
Editor's note—refer to figure AP31A
AO17AO19.5
Permanently fixed external screening devices complement the
building's external materials and finishes and may incorporate
solid translucent screens, shutters, perforated panels or
trellises which have a maximum of 50% openings.
Editor's note—refer to figure AP31B
PO18PO20 AO18AO20.1
Mechanical plant, vehicle manoeuvring, utilities and communal Communal outdoor recreational facilities including swimming
outdoor recreation uses: pools, spas and sports courts are:
(a) do not have an adverse effect on the amenity enjoyed by (a) setback at least 12 metres from the boundary of land in a
users of adjacent or nearby premises through emission residential zone and screened by a 5 metre wide buffer
of noise, light, fumes or smoke; and densely planted with trees and shrubs including species
(b) do not cause unreasonable disturbance to local fauna from 1 metre to 8 metres in height; or
through light or smoke emissions. (b) located internally to the arrangement of buildings on the
site; and
(c) not used between the hours of 9:00pm and 6:30am the
following day.
AO18AO20.2
For a lit sports court:
(a) the court is located at least 60 metres from the external
wall of an existing or approved dwelling on adjoining or
nearby premises (as measured from the centre line of the
court); and
(b) the vertical illumination resulting from direct, reflected or
other incidental light emanating from the site does not
exceed 8 lux when measured at any point 1.5 metres
outside the boundary and at any level from ground level
upward; and
(c) any floodlighting is restricted to the types that give no
upward component of light were mounted horizontally (i.e.
a full cut off luminaire).
AO18AO20.3
Mechanical plant is
(a) located at least 2 metres from the side or rear property
boundaries;
(b) where located at ground level, screened by fencing 1.5
**Draft**New Noosa Plan for the purpose of Community Consultation Round 2 2019 Page 8 of 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.