APPENDIX F - Acoustic Report

Attached to the e-mail MCU18/0204 - Development Application - 6 Heron Street, Peregian Beach.

of 33

Page text shows just the words. Original shows the document exactly as it was published.

          RENZO TONIN RON RUMBLE                                                                                            1 SEPTEMBER 2017




          Table 2: Existing average ambient noise levels - 18 Kingfisher Drive, Peregian Beach

                                                                            Average Noise Levels (dBA)
                     Time of Day
                                                  L01               L10                 L90 (RBL)              Leq              Lmax

              Day (7am-6pm)                       66                59                     48                  57                74

              Evening (6pm-10pm)                  62                56                     49                  55                69

              Night (10pm-7am)                    56                53                     46                  52                62


          The meteorological conditions over the monitoring period were conducive for measuring noise under
          typical conditions. There was no rain over the monitoring period and negligible wind with relatively calm
          conditions experienced over most days and nights. Observations during our site inspections noted that
          ambient noise was mainly due to birds, wind (rustling of leaves in trees), traffic and surf.


          The measurement procedures used and the results reported in this document were conducted in
          accordance with Renzo Tonin and Associates' Quality Assurance System, Australian Standard 1055-1989
          "Acoustics - Description and Measurement of Environmental Noise" and the DEHP's Noise Control Manual
          (August 2013).




          4            Noise Emissions Criteria

          4.1          The Noosa Plan

          Section 14.12 of The Noosa Plan outlines Specific outcomes, probable solutions and acceptable solutions
          for Division 3-Business Uses Code.


          Specific Outcomes O7 and O8 relate to Outdoor dining areas, which are outlined in Table 14-5 New
          Business Uses Within Existing Buildings in Established Centres), i.e.:

Specific Outcomes                                                   Acceptable Solutions

Amenity

O4        The new use is operated in a manner that avoids noise           S4.1    Where the site adjoins land in a residential zone,
          emissions that unreasonably diminish the amenity of the                 the use does not operate outside of the hours of
          area or surrounding uses.                                               7:00am to 9:00pm.

Outdoor Dining Areas

O7        Outdoor dining areas are designed and                           S7.1    Walls to outdoor dining areas are—
          located so that—                                                        a) if facing a roadway or other public area, transparent;
          a) structures are aesthetically pleasing and in keeping                 b) not made of flexible, roll-up or drop plastic sheeting;
          with the existing character of the area, including the                  c) separated from the floor and any roof by a minimum
          architecture of the associated building;                                vertical gap of 500mm;
          b) outdoor dining adds to the landscaped streetscape                    and
          without increasing perceived building bulk;
                                                                                  d) if detachable or collapsible, are only used during
          c) temporary walls or roofs are stored when not in use                  inclement weather;
          and secured at all times;
                                                                                  AND
          d) adequate air movement is available; and




          COX ARCHITECTURE                                                              OUTDOOR RESTAURANT DECK (LEVEL 2) - 6 HERON STREET,
          QB143-01F02 ACOUSTIC REPORT (2)                                                                                   PEREGIAN BEACH
                                                                            4                                  PATRON NOISE ASSESSMENT
Log in to download the original file

APPENDIX F - Acoustic Report.pdf · 4.3 MB (large file)