Council archive · source document
Structural Plans · MCU21/0097
Plans and drawings: the text below has words only, no drawings.
IN-PLANE FIXING ON TOP FIXING CENTRE FIXING Type 1 - 1 Triple grip with 4/2.8 nails each end
R1 - 360x42 LVL15 Rafters @ 600 crs min Type 2 Type 1 Type 2 - Pryda Framing Bracket with 6 / 35mm long x 3.15 nails
R2 - 360x42 LVL15 Continuous Rafters @ 900 crs min Type 2 Type 1 Type 3 each end each side
Type 3 - Cyclone Strap 30x0.8 GI strap & 6/2.8 nails each end
R3 - 300x42 LVL15 Continuous Rafters @ 900 crs min Type 2 Type 1 Type 3
(250mm min down stud otherwise must go to a Type 4)
R4 - 300x42 LVL15 Rafters @ 900 crs min Type 2 Type 1 Type 4 - Double Triple grip with 6/2.8 nails each end LINDSAY CONSULTING PTY