Council archive · source document
Structural Plans · MCU21/0097
Plans and drawings: the text below has words only, no drawings.
FRONT VIEW SIDE VIEW
LINDSAY CONSULTING PTY
LTD
460 UB 74.6
S2, fy = 300
2M16 8.8N/TB
200mm min embedment
40
90 100 100
175
20 36 70 49
43
43
58 100 58
107
310 UB 32.0
215
S1, fy = 320
215.0x175.0x12.0 mm PLATE
(fy = 260 MPa, fu = 410 MPa)
10.0 mm CFW SP (fu = 490.00 MPa) WELDS
4M24 8.8N/S (fu = 830.00 MPa) BOLTS
95x40 mm Top Cope
95x40 mm Top Cope
80
20 30 30
35
35
310 UB 46.2 230.0x80.0x6.0 mm PLATE
(fy = 280 MPa, fu = 410 MPa)
70 70 45
S3, fy = 300 250.0x166.0x6.0 mm BEARING PACKER
119
6.0 mm CFW SP (fu = 490.00 MPa) WELDS
40 170 40 (fy = 280.00 MPa, fu = 410.00 MPa) 3M20 8.8N/S (fu = 830.00 MPa) BOLTS
310 UB 46.2
230
4M12 8.8N/TB
3.0 mm CFW GP PACKER WELDS S3, fy = 300
75x35 mm Top Cope
75x35 mm Bottom Cope
75x35 mm Top Cope
45
75x35 mm Bottom Cope
See the original