NOTES
1. STRUCTURAL
a) Concrete
- F'c = 25MPa at 28 days. 32MPa if within 1km of coastline
- Concrete shall comply with AS2783
- Concreting shall be carried out in one continuous operation by pneumatic spraying process
- Shade concrete and keep moist for 7 days.
- Exposure Classification (AS2783) - B2.
b) Reinforcement Fy = 250MPa. S12 bars throughout, lap 400 where required.
c) Foundations
Bars shall be tied securely in position.
- Cover shall be 65mm to vertical reinforcement to the inside face.
- Excavation shall follow contours of pool shape. Where over excavation occurs fill with concrete
- Foundation material shall be uniform over entire pool base, if not refer to Engineer
- In clay or rocky ground use 75mm thick layer of 20mm nominal gravel under base
- Minimium safe bearing capacity - 100kPa
- Pool walls shall be poured against undisturbed natural ground, if not refer to Structural Engineer.
aA
Total length 16700 MAX
d) Design - Design suitable for sites up to and including Class H (AS2870-2011)
- If pool is located in fill or aboveground refer to Structural Engineer.
- Drawing not to be used for pools in Exposure Classification C (AS2783)
- Walls have not been designed for cantilever walkways
2. CONSTRUCTION
a) Construction shall comply with AS2783.
3. GENERAL
a) Ground water pressure shall be relieved by Hydrostatic valve as shown.
b) Surface water shall be prevented from penetrating down beside pool wall by
grading surrounding areas away from the pool
c) Security fencing shall be as required by the Local Authority.
d) Finishes to pool surface shall be as detailed by Pool Contractor.
e) All hydraulic equipment (eg. pump, filter, hydrostatic relief valve, skimmer box etc.)
shall be as specified by the Pool Contractor
900 wide x 75 thick slab all round with F52
fabric CP or pavers with cement stabilized
B filling sand. Refer Note 3{b) ————]
300
Maximium surface area - 100m?
Finish to Clients or
Contractors requirements ™
Water Level
200 | 150 mw
{-: ~]
3 /S12
4 | inbondbeam *
$
SS
WALLS
REFER TABLE FOR
REINFORCEMENT
Earth wire to reinforcement
Joes to dwelling earth system
300 Varies
Washed gravel to underside
of pool, refer Note ‘{c)
BASE
S12 Verticals @ 300 crs
$12 Horiz @ 300 crs
Water Level
NOTE o
Where pool wall height (H) exceeds 3
x 1200 but less than 1500
provide intermediate vertical $12 bars
as shown dotted.
(ie. S12 bars in this area at 150 c/c)
THIS IS BASED ON 150 THICK - REFER
TABLE FOR THICKER POOL SHELL — gq
R/2
SECTION B-B
Hydrostatic relief valve _
| 600
100
Overall depth (D)
2250 MAX
DIA 200 Anti vortex
cover
Unreinforced cutoff wall
REQUIRED FOR
(CLASS H2 & E SITES)
Dia 40 suction line 300
to filter (Client option)
300
Sump containin 8 a Ss
nn | d= aL. e
600 Sa oO | oO
5
LONGITUDINAL SECTION COPING VARIATION WET EDGE DETAIL
300 Varies 4
\
Po]
SECTION A-A
LINDSAY CONSULTL
OFF. 2¢/82 PARKER ATREET, MAROOGAYDORE PH 5
THIS DRAWING REMAINS HE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
PAUL CLOUT DESIGN
PROPOSED RESIDENCE
NO.30 THE PROMONTORY
NOOSAVILLE
DRAWING TITLE
POOL DETAILS
SCALES
SURVEY DATUM
ASSOCIATED CONSULTANTS
REVISION LIST
A [ORIGINAL ISSUE 20/05/21
‘ompurer File
210531FD.DWG
DRAWING NUMBER SHEET] REV.
21-0531-F 14 14) A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.