Original source · versioned page text
2022-04-21 Ordinary Meeting Agenda
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
ORDINARY MEETING AGENDA 21 APRIL 2022
a. The frontage of proposed Lot 8 must be completed prior to the sealing of the survey plan
for Stage 1
b. The remainder of the frontage, including the proposed intersection, must be completed
prior to the sealing of the survey plan for Stage 2. The intersection must be constructed
generally in accordance with drawing No. 21598-P002, Revision B prepared by TOD
engineers.
Condition 48 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
infrastructure.
49. A new intersection must be constructed joining Glenridge Drive with the new road. The works
must be undertaken in accordance with an Operational Works approval and be completed prior
to the sealing of the survey plan for Stage 2. The intersection must be constructed generally
in accordance with drawing No. 21598-P002, Revision B prepared by TOD engineers, the
Engineering Report Document No. 21598_RP1, Revision B prepared by TOD engineers dated
24 March 2022 and must include in particular:
a. an intersection with vehicle priority maintained on Glenridge Drive
b. provision of sight distances adequate for the design speed of the road
c. truncation of the new property boundaries
Condition 49 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
infrastructure.
New Roads
50. The new road as shown on the Approved Plans must be constructed and dedicated as “road”.
The works must be undertaken in accordance with an Operational Works approval and be
completed prior to the sealing of the survey plan for Stage 2. The works must include in
particular:
a. a reserve width of 20 metres with widening at the cul-de-sac head and generally in
accordance with the approved plan
b. a cross section generally in accordance with drawing No. 21598-P002, Revision B
prepared by TOD engineers
c. a cul-de-sac head generally in accordance with drawing No. 21598-P002, Revision B
prepared by TOD engineers and Council’s Planning Scheme Policy 6 – Engineering
Design Standards
d. table drains and culvert drainage generally in accordance with drawing No. 21598-P002,
Revision B prepared by TOD engineers and the approved flood investigation
Condition 50 is imposed pursuant to s145 of the Planning Act 2016 being non-trunk
infrastructure.
Property Access and Driveways
51. A residential driveway must be constructed to all lots in the relevant stage. The works must be
undertaken in accordance with an Operational Works approval and:
a. be generally in accordance with drawing No. 21598-P002, Revision B prepared by TOD
engineers and
b. be generally in accordance with Council’s Standard Drawing RS-056 and any associated
addendum
c. include the access driveway servicing Lots 3 & 5.
52. The existing vehicle access to McKinnon Drive is to be wholly removed and the area
revegetated as part of these works.
53. Vehicle access to Lots 1 - 8 is limited to the constructed driveway only. A clause must be
included in the contract of sale for Lots 1 - 8 which requires vehicle access to be from the
Page 25 of 33
See the original
The page text is free to read. Viewing or downloading an original file needs an account.