2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
Including amendments to 3 July 2017
The Noosa Plan
Flooding and drainage 46
O8 Buildings and other works are designed and S8.1 For new buildings or structures or
sited to— additions of more than 50m2 gross floor area
a) provide flood free access to premises and to an existing building or structure, floor
flood free habitable areas; levels for habitable rooms are—
b) allow only minor, short term and infrequent a) for areas where minimum floor levels
flooding of non-habitable areas; are available—not less than the
c) ensure carparking areas can be adequately specified level;
drained; b) for areas where flood modelling is
d) ensure drainage does not adversely impact available—a minimum of 300mm
upon other premises; and above the modelled flood level; and
e) ensure filling or excavation does not c) for areas where flood modelling is not
adversely impact upon other premises by— available, a minimum of 300mm above
i. causing ponding on the site or nearby the highest known flood level;
land; AND
ii. increasing flooding, which adversely S8.2 Where Council infrastructure is
affects the safety or use of any land available—
upstream and downstream; and a) any drainage (from buildings and land)
iii. adversely affecting the flow of water in flows to that infrastructure; and
any overland flow path. b) the infrastructure has the capacity to
accept any additional loading.
AND
S8.3 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping; or
S8.4 Basements for residential uses have
flood immunity above the 1%AEP defined
flood event where alternative means to
mechanical pumping are used to achieve
such immunity; or
S8.5 Basements for non-residential uses
have flood immunity above the 1%AEP
defined flood event that may be achieved by
means of mechanical pumping only where
the mechanical feature is installed with
adequate holding tanks and an alternative
back up power source.
Roof form
O9 Rooflines— S9.1 The main roof of the building has a
a) contribute positively to the local skyline; roof pitch no less than 5 degrees and has
b) complement the character of the locality; minimum 600mm eaves to at least 75% of
c) are articulated, pitched or skillion; the perimeter of the building;
d) avoid low pitched (eg. less than 5 degrees) or AND
box profiles/parapets; S9.2 Buildings and structures do not include
e) do not create opportunities for residents to roof top terraces.
overlook the private open space areas of
neighbouring properties.
46
Information on minimum floor levels and flood levels for some parts of the Shire is available from Council. These
provisions are not limited to areas shown as Flood Hazard Areas on overlay maps 1.3-9.3.
5-29