2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections

of 862

Page text shows just the words. Original shows the document exactly as it was published.

                        column 1                                          column 2




                                                                                                       Including amendments to 3 July 2017
                  Specific Outcomes                                   Probable solutions




                                                                                           The Noosa Plan
Site cover, gross floor area and plot ratio
O9 The site cover, gross floor area and plot
                                                          No solution provided
ratio of buildings and other roofed structures—
a)     results in a building scale that is compatible
       with surrounding development;
b)     does not present an appearance of bulk to
       adjacent properties, roads or other areas in
       the vicinity of the site;
c)     maximises the retention of existing
       vegetation and allows for soft landscaping
       between buildings;
d)     allows for adequate area at ground level for
       outdoor recreation, entertainment, clothes
       drying and other site facilities; and
e)     facilitates onsite stormwater management
       and vehicular access.

O10 Site cover does not exceed—
a) for a class 1 or class 10a building within the
   Detached Housing Zone, —
     i for a single storey building - 50%; or
     ii for a building of 2 or more storeys -
         50% on the ground floor and 30% for
         the upper storey(s), or 40% for all
         storeys for a building of 2 or more
         storeys;
b) for other classes within the Detached
   Housing Zone - 40%;
c) for the Semi-Attached Housing Zone—40%;
   or
d) for the Attached Housing Zone—40%
e) for the Community Services Zone—50%

O11 For Multiple Housing Type 2 buildings
have a maximum plot ratio of 0.45:1.

O12 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4, or the accommodation
unit component of an Entertainment and dining
business Type 3—maximum gross floor area is
equivalent to the maximum allowable population
in persons multiplied by 40m 2.

O13 For the Business Centre Zone plot ratio
does not exceed—
a) 0.8:1 for site areas up to and including
    2,000m2; and
b) 0.3:1 for the balance of a site over 2,000m 2.




                                                   6-43
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.