Original source · versioned page text
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
Including amendments 3 July 2017
The Noosa Plan
Flooding and drainage74
O14 Buildings and other works are designed S14.1 For new buildings or structures or
and sited to— additions of more than 50m2 gross floor area to
a) provide flood free access to premises and an existing building or structure, floor levels for
flood free habitable areas; habitable rooms are—
b) allow only minor, short term and infrequent a) for areas where minimum floor levels are
flooding of non-habitable areas; available—not less than the specified
c) ensure carparking areas can be adequately level;
drained; b) for areas where flood modelling is
d) ensure drainage does not adversely impact available—a minimum of 300mm above
upon other premises; and the modelled flood level; and
e) ensure filling or excavation does not c) for areas where flood modelling is not
adversely impact upon other premises by— available, a minimum of 300mm above
i. causing ponding of water on the site the highest known flood level;
or nearby land; AND
ii. increasing flooding, which adversely S14.2 Where Council infrastructure is
affects the safety or use of any land available—
upstream and downstream; and a) any drainage (including buildings and
iii. adversely affecting the flow of water yards) flows to that infrastructure; and
in any overland flow path. b) the infrastructure has the capacity to
accept any additional loading;
AND
S14.3 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping; or
S14.4 Basements for residential uses have
flood immunity above the 1%AEP defined
flood event where alternative means to
mechanical pumping are used to achieve such
immunity; or
S14.5 Basements for non-residential uses
have flood immunity above the 1%AEP
defined flood event that may be achieved by
means of mechanical pumping where the
mechanical feature is installed with adequate
holding tanks and an alternative back up
power source.
74
Information on minimum floor levels and flood levels for some parts of the Shire is available from Council. These
provisions are not limited to areas shown as Flood Hazard Areas on overlay maps OM1.3-9.3.
6-44
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.