                                                                                                                        Including amendments to 3 July 2017
              Specific Outcomes                                      Probable solutions




                                                                                                            The Noosa Plan
Sloping sites
O15 On sloping sites, buildings and structures          S15.1 Buildings are of split level design that
are designed to maximise the use of natural             step down the slope or have a suspended floor
slope and minimise the need for cut and fill.           construction; (See Figure 6.1 below)
                                                        AND
                                                        S15.2 Cut or fill is less than 2m in depth;
                                                        AND
                                                        S15.3 The distance between the ground and
                                                        the lowest part of the floor of the building does
                                                        not exceed 3m.
                                                        Figure 6.1—Design for sloping site
                                                        (suspended floor)




Roof form
O16 Roof forms—                                          S16.1 With the exception of industrial
a)    contribute positively to the local skyline;        buildings the main roof of the building has a
b)    complement the low rise character of the           roof pitch no less than 12 degrees and has
      locality;                                          minimum 600mm eaves to at least 75% of the
c)    use simple traditional roof designs, such as       perimeter of the building;
      hipped, gabled or skillion; and                    AND
d)    do not create opportunities for residents to      S16.2 Building and structures do not include
      overlook the private open space areas of          rooftop terraces.
      neighbouring properties.
Public transport node
O17 An accessible and safe public transport             S17.1 A public transport node is located within
node is established and operated within Cooroy          Cooroy as identified in Schedule 5 on Map 1.
that—
 a) links public transport services to other
    centres and destinations throughout the
    Sunshine Coast; and
 b) forms part of an integrated transport network
    that is accessible via pedestrian and bicycle
    pathways.




                                                 6-45
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.