The Noosa Plan
between buildings;
d) allows for adequate area at ground level for
outdoor recreation, entertainment, clothes
drying and other site facilities; and
e) facilitates onsite stormwater management
and vehicular access.
O10 Site cover—
a) for a class 1 or class 10a building within the
Detached Housing Zone, does not exceed—
i for a single storey building - 50%; or
ii for a building of 2 or more storeys - 50%
on the ground floor and 30% for the
upper storey(s), or 40% for all storeys for
a building of 2 or more storeys;
b) for other classes within the Detached House
Zone does not exceed 40%;
c) for the Semi-Attached Housing Zone does not
exceed 40%;
d) for the Attached Housing Zone does not
exceed 40%; or
e) for the Visitor Mixed Use Zone does not
exceed 45%.
O11 For Multiple housing Type 2, buildings
have a maximum plot ratio of 0.45:1.
O12 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4 and the accommodation
unit component of an Entertainment and dining
business Type 3 (hotel)—the maximum a gross
floor area is equivalent to the maximum allowable
population in persons multiplied by 40m 2.
O13 For the Visitor Mixed Use Zone the
maximum a gross floor area is equivalent to the
maximum allowable population in persons
multiplied by 40m2, provided that gross floor area
does not exceed a total of 13,600m 2.
O14 For the Neighbourhood Centre Zone and the
Business Centre Zone, the maximum plot ratio
does not exceed –
a) 0.8:1 for the first 2,000m 2 of site area; plus
b) 0.3:1 for the balance of the site area in excess
of 2,000m2.
Roof form
O15 Roof forms— S15.1 The main roof of the building has a
a) contribute positively to the local skyline; roof pitch no less than 5 degrees and has
b) complement the character of the locality; minimum 600mm eaves to at least 75% of
c) use soft and articulated, pitched, skillion or the perimeter of the building;
curved roof forms; AND
d) avoid low pitched (eg. less than 5 degrees) S15.2 Buildings and structures do not include
or box profiles/parapets; and roof top terraces.
e) do not create opportunities for residents to
overlook the private open space areas of
9-35