                      column 1                                           column 2
                 Specific Outcomes                                   Probable solutions




                                                                                                                     Including amendments to 3 July 2017
                                                                                                         The Noosa Plan
      between buildings;
d)    allows for adequate area at ground level for
      outdoor recreation, entertainment, clothes
      drying and other site facilities; and
e)    facilitates onsite stormwater management
      and vehicular access.

O10 Site cover—
a) for a class 1 or class 10a building within the
   Detached Housing Zone, does not exceed—
    i    for a single storey building - 50%; or
    ii   for a building of 2 or more storeys - 50%
         on the ground floor and 30% for the
         upper storey(s), or 40% for all storeys for
         a building of 2 or more storeys;
b) for other classes within the Detached House
   Zone does not exceed 40%;
c) for the Semi-Attached Housing Zone does not
   exceed 40%;
d) for the Attached Housing Zone does not
   exceed 40%; or
e) for the Visitor Mixed Use Zone does not
   exceed 45%.

O11 For Multiple housing Type 2, buildings
have a maximum plot ratio of 0.45:1.

O12 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4 and the accommodation
unit component of an Entertainment and dining
business Type 3 (hotel)—the maximum a gross
floor area is equivalent to the maximum allowable
population in persons multiplied by 40m 2.

O13 For the Visitor Mixed Use Zone the
maximum a gross floor area is equivalent to the
maximum allowable population in persons
multiplied by 40m2, provided that gross floor area
does not exceed a total of 13,600m 2.

O14 For the Neighbourhood Centre Zone and the
Business Centre Zone, the maximum plot ratio
does not exceed –
a) 0.8:1 for the first 2,000m 2 of site area; plus
b) 0.3:1 for the balance of the site area in excess
    of 2,000m2.

Roof form
O15 Roof forms—                                           S15.1 The main roof of the building has a
a)   contribute positively to the local skyline;          roof pitch no less than 5 degrees and has
b)   complement the character of the locality;            minimum 600mm eaves to at least 75% of
c)   use soft and articulated, pitched, skillion or       the perimeter of the building;
     curved roof forms;                                   AND
d)   avoid low pitched (eg. less than 5 degrees)         S15.2 Buildings and structures do not include
     or box profiles/parapets; and                       roof top terraces.
e)   do not create opportunities for residents to
     overlook the private open space areas of



                                                  9-35
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.