                                                                                                              The Noosa Plan
Garages and carports
O46 Garages, carport structures and vehicle                S46.1 Garages and carports—
manoeuvring areas are designed and sited to—               a) have a front boundary setback of at least
a)   provide for resident and visitor parking;                  6m; and
b)   visually integrate with the building and to           b) present a minimum width to the
     not dominate the street front;                             streetscape (the total width of garage
c)   allow opportunity for landscaping to screen                doors is no more than 6m or 50% of the
     vehicle parking and manoeuvring areas;                     frontage width, whichever is the lesser,
d)   minimise the number of driveway                            where the structure faces the street); or
     accesses; and                                         c) that are visible from, but do not face the
e)   allow safe and efficient access to and                     street, include windows or other
     egress from the premises.                                  articulation and have a 6m vegetated
                                                                buffer between the structure and the road
                                                                frontage;
                                                           AND
                                                           S46.2 Where multiple lock up garages face the
                                                           street garage doors are stepped back a
                                                           minimum of 600mm from each other, in
                                                           relation to the frontage or are separated by at
                                                           least 1.5m;
                                                           AND
                                                           S46.3 Garages, carports and uncovered
                                                           spaces are designed to allow vehicles to enter
                                                           and exit the site in a forward gear through a 3-
                                                           point turn maximum;
                                                           AND
                                                           S46.4 The development provides for shared
                                                           driveways to minimise the number of access
                                                           points, except on sites with more than one
                                                           street frontage, where garages or carports in
                                                           the development front separate streets.

Front fences & walls
O47 Front fences and walls are designed and                S47.1 Front fences or walls are setback an
sited to—                                                  average of 1 metre and are articulated to
a)     contribute to the attractiveness of the street;     provide visual interest by stepping the design
b)     be compatible with the existing streetscape         at maximum 5m intervals;
       character;                                          AND
c)     relate to the architectural period of the           S47.2 The area of land between the fence
       building;                                           and the front property boundary shall be
d)     avoid interference with the movement of             densely landscaped to screen any fencing
       surface stormwater;                                 from the street;
e)     allow for casual surveillance from the street       AND
       or on main roads, mitigate traffic noise;           S47.3 Any fencing on the boundary which is
f)     provide for planting in front of high solid         not screened by vegetation is either less than
       fences and walls; and                               1.2m high or of an open construction.
g)     ensure planting between the front fence
       and the footpath does not create an
       impediment for pedestrians using the
       footpath.




                                                    9-49
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.